Mnemonic
Name
OC
Output
Control
OM
Output Muting
PA
Reset Stored
Configuration
14
Quasonix, Inc.
Description
Report or set the channel
source values
Examples:
OC
Show current OC
settings
OC D
Set the default
outputs
OC c s Set the channel and
clock source
For detailed syntax
information, refer to
Appendix C
Report or set the operation
of clock and data output
muting; clock and data
outputs can be disabled after
some period of time without
lock
Examples:
OM
Show the output
muting state
OM 0
Disables output
muting
OM 1
Enables output
muting
OM T x Sets the delay
between loss of lock and
muted outputs in
milliseconds from 0 to 46016
Resets ALL parameters in
ALL waveform modes to the
factory default state and sets
the receiver to the lowest
default mode and lowest bit
rate
Refer to Appendix E for a list
of factory default values by
mode
TM
Compact RDMS
Option (s)
Required
Advanced
Command
8F and -37
Basic
Standard
Advanced
Command
Standard
Basic
Telemetry Receiver
Basic or
Mode
Restriction
None
None
None