Mnemonic
Name
SY
System Status
Tracking
TO
Tape Output
17
Quasonix, Inc.
Description
Displays the system status
of the receiver
The first argument specifies
the period, in milliseconds,
between status updates.
Zero (0) disables continuous
monitoring.
The second argument
specifies the number of
status lines between header
output.
Examples:
SY
Displays current
status report settings
SY 5
Sets status output
period to 5 milliseconds
SY 5 100
Sets status
header output once every
100 status updates
The SY command reports
system status information
about the timing and
frequency tracking loops, as
well as mod scaling, lock
indication and eb/n0 data.
This command is very
effective for troubleshooting
link issues.
Displays the status of the