Mnemonic
Name
AV
Manual
Attenuator
Control
BE
Bit Error Rate
BL
Break Lock
BM
Bit Rate
Measurement
BR
Bit Rate
CC
Convolutional
Decoder
Enable
8
Quasonix, Inc.
Description
Report or set the value of the
input attenuator
Valid range is 0 to 124 dB
Examples:
AV
Report the input
attenuator setting
AV 0
Set input attenuator
to 0 dB
AV 124 Set input attenuator
to 124 dB
For Bit Error Rate
commands and information,
refer to Appendix A, Bit Error
Rate Testing.
Breaks false locks
No additional parameters
Report bit rate measurement
Report or set baseband bit
rate
Examples:
BR
Report the bit rate
setting
BR 5
Set bit rate to 5
Mbps
BR 0.6 Set bit rate to 600
Kbps
Enables or disables the
convolutional decoder
Examples
CC
Report convolutional
decoder state
CC 0
Set the convolutional
decoder to Disabled
CC 1
Set the convolutional
decoder to Enabled
TM
Compact RDMS
Option (s)
Required
Advanced
Command
Standard
Basic
Standard
Advanced
Command
Standard
Basic
Standard
Basic
Standard
Basic
K7
Basic
Telemetry Receiver
Basic or
Mode
Restriction
None
None
PSK
(legacy)
PSK
(legacy)
For Asynch
PSK
(legacy)
modes, BR
A and BR
B must be
specified
separately
PSK
(legacy)

Advertisement