Distilled water or deionized water is
recommended for use in engine cooling systems.
DO NOT use the following types of water in cooling
systems: Hard water, softened water that has been
conditioned with salt and sea water.
If distilled water or deionized water is not available,
use water with the properties that are listed in Table
13 .
Table 13
Acceptable Water
Property
Chloride (Cl)
Sulfate (SO
)
4
Total Hardness
Total Solids
Acidity
For a water analysis, consult one of the following
sources:
• Local water utility company
• Agricultural agent
• Independent laboratory
Additives
Additives help to protect the metal surfaces of the
cooling system. A lack of coolant additives or
insufficient amounts of additives enable the following
conditions to occur:
• Corrosion
• Formation of mineral deposits
• Rust
• Scale
• Foaming of the coolant
Many additives are depleted during engine operation.
These additives must be replaced periodically.
Additives must be added at the correct concentration.
Over concentration of additives can cause the
inhibitors to drop out-of-solution. The deposits can
enable the following problems to occur:
• Formation of gel compounds
• Reduction of heat transfer
• Leakage of the water pump seal
• Plugging of radiators, coolers, and small passages
Maximum Limit
40 mg/L
100 mg/L
170 mg/L
340 mg/L
pH of 5.5 to 9.0
Glycol
Glycol in the coolant helps to provide protection
against the following conditions:
• Boiling
• Freezing
• Cavitation of the water pump
For optimum performance, Perkins recommends a
1:1 mixture of a water/glycol solution.
Note: Use a mixture that will provide protection
against the lowest ambient temperature.
Note: 100 percent pure glycol will freeze at a
temperature of −13 °C (8.6 °F).
Most conventional antifreezes use ethylene glycol.
Propylene glycol may also be used. In a 1:1 mixture
with water, ethylene and propylene glycol provide
similar protection against freezing and boiling. Refer
to Table 14 and refer to table 15 .
Table 14
Ethylene Glycol
Concentration
50 Percent
60 Percent
NOTICE
Do not use propylene glycol in concentrations that ex-
ceed 50 percent glycol because of the reduced heat
transfer capability of propylene glycol. Use ethylene
glycol in conditions that require additional protection
against boiling or freezing.
Table 15
Propylene Glycol
Concentration
50 Percent
To check the concentration of glycol in the coolant,
measure the specific gravity of the coolant.

Coolant Recommendations

• ELC
• SCA
Supplement Coolant Additive
• ASTM
American Society for Testing and
Materials
The following two coolants are used in Perkins
diesel engines:
75
Refill Capacities
Fluid Recommendations
Freeze Protection
−36 °C (−33 °F)
−51 °C (−60 °F)
Freeze Protection
−29 °C (−20 °F)
Extended Life Coolant

Advertisement