Section 300~Installation
Table S-11. Maximum distrurces for SLTA installation
Wiring
Max. distance (in feet) between
the DBS and SLTA
AWG 22
300' or 10 n
AWG 24
190' or 10 Sz
AWG 26
120' or 10 Q
4.
5.
6.
7.
8.
9.
DBS-70-300
Connect the GND and +24V leads on the SLTA to the DBS connector
panel. Be sure the wires do not touch each other or touch the metal
frame housing.
Turn on the DBS power.
Connect the "T" and "R" leads to the digital extension ports on
as per Figure 5-21. One digital extension port is required for each
Connect the SLT "T" and "R" leads to the SLTs.
Install the cover on the SLTA.
DBS Manual - Issued 8/l/95
Chapter 5. Peripheral Equipment
Max. distance (in feet) between
the SLTA and the SLT
3000' or 100 SI
1900' or 100 rZ
1200' or 100 n