Panasonic CS-E9CKP Service Manual page 44

Hide thumbs Also See for CS-E9CKP:
Table of Contents

Advertisement

CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oy
CARE AND MAINTENANCE
I Cleaning the Indoor Unit and Remote
Control
• Wipe gently with a soft, dry cloth.
• Do not use water hotter than 40˚C or polishing fluid
to clean the unit.
I Cleaning the Air Filter
(Recommendation:- If the unit is operated in a dusty
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce cooling
or heating efficiency)
1
Remove dirt using a vacuum cleaner.
2
Wash back of the air filter with water.
3
If badly soiled, wash it with soap or a mild household
detergent.
4
Let it dry and reinstall it.
Be sure the "FRONT" mark is facing you.
* Damaged air filter.
Consult the nearest authorized dealer.
Part No.: CWD001047.
• Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the unit.
I Cleaning the Front Panel
(Must be removed before washing)
1
Raise the front panel higher than the horizontal and
pull to remove it.
2
Gently wash with water and a sponge.
• Do not press the front panel too hard when washing.
• When use kitchen cleaning fluid (neutral detergent),
rinse throughly.
• Do not dry the front panel under direct sunlight.
3
To fix the front panel, raise the front panel
horizontally, match the protruding portion on the
indoor unit to the fulcrum and push into place.
Protruding portion on indoor unit
HELPFUL INFORMATION
I Auto Operation Button
• Raise the front panel and press.
G Automatic Operation
• If the remote control fails to function or has been
misplaced, press the Auto Operation button to start
the Automatic operation.
• The Automatic operation will be activated
immediately once the Auto operation button is
pressed. However, temperature cannot be adjusted
in this operation.
• The power indicator on the indoor unit will blink until
the operation mode is selected automatically.
• To cancel this operation, press once more.
I Air Purifying Filters
1
Raise the
front panel
2
Remove the air filters
G Triple Deodorizing Filter
• Absorb odours produced by wall paper, construction
material and living environment.
• Reusable.
• Vacuum, place under direct sunlight for 6 hours and
fit it back in place.
(Recommended : every 6 months)
G Catechin Air Purifying Filter
• The filter is coated with catechin to prevent growth
of bacteria and viruses.
• Reusable.
• Vacuum and fit it back in place
(Recommended : every 6 months)
Recommended to change these filters every 3 years.
Do not reuse damaged filters.
Consult the nearest authorized dealer to purchase a
new filter.
Catechin Air Purifying Filter No.: CZ-SF70P
Triple Deodorizing Filter No.: CZ-SFD72P
If you operate the air conditioner with dirty filters:-
– Air is not purified
– Cooling capacity decreases
Fulcrum
– Foul odour is emitted
I Auto Restart Control
• If there is a power failure, operation will be
automatically restarted under the previous operation
mode and airflow direction when power is resumed.
(When the operation is not stopped by remote
control).
• If you do not want the unit to restart automatically
when power is resumed, switch off the power
supply.
• If you do not require Auto Restart Control, consult
your dealer.
• Auto Restart Control is not available when Timer
Mode is set.
• When the operation restarts, the outdoor unit will
operate only after 3~4 minutes.
I Timer Setting
• When power failure occurs, the timer setting will be
cancelled. Once power is resumed, reset the timer.
I Thunder and Lightning
• This air conditioner is equipped with a built-in surge
protective device. However, in order to further
protect your air conditioner from being damaged by
abnormally strong lightning activity, you may switch
off the main power supply and unplug from power
socket.
I Voltage fluctuation
• The outdoor unit stops operation frequently due to a
fluctuation in the voltage. Consult your dealer.
www.ilmalämpöpumput.com
44
I Pre-season Inspection
G Is the discharged air cold/warm?
Operation is normal if 15 minutes after the start of
operation, the difference between the air intake and
outlet vents temperature is:-
Triple Deodorizing
Filter
G Are the air intake or outlet vents of the indoor or
outdoor units obstructed?
Catechin Air
G Are the remote control batteries weak?
Purifying Filter
If the remote control display appears weak, replace
the batteries.
I When the Air Conditioner is Not Used
for an Extended Period of Time
1
To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using:-
2
Turn off the power supply and unplug.
Note: If the unit is not switched off by the remote
control, it will start operating when you plug in
(because the unit is equipped with Auto Restart
Control).
3
Remove the remote control batteries.
I Recommended Inspection
• After used over several seasons, the unit will
become dirty and thus decreases the unit's
performance. Depending on the operation
conditions, a dirty unit may produce odour and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
regular cleaning. (Consult an authorized dealer).
ENERGY SAVING AND OPERATION
HINTS
Here are some useful tips for optimum performance
and cost-effective operation.
I Setting the Temperature
• Approximately 10% of electricity can be saved.
• Set the temperature higher or lower than the
desired temperature.
Cooling Operation : 1°C higher
Heating Operation : 2°C lower
I Air Filters and Air Purifying Filters
• Clean the air filters every 2 weeks and the Air
Purifying Filters every 6 months.
• Dirty filters may reduces cooling or heating
efficiency.
I Keep All Doors and Windows Closed
• Otherwise, cooling or heating performance will be
reduced and electricity cost is wasted.
I Outdoor Unit
• Do not block the air outlet vents. Otherwise, it will
lower the cooling or heating performance.
I Timer Mode
• To prevent wastage of electricity, use Timer when
going out.
I Avoid Direct Sunlight
• Keep curtains or drapes closed to avoid direct
sunlight during cooling operation.
COOL – 8°C or above
HEAT – 14°C or above
FAN operation