8.1.2.
Frequency Instruction for Compressor Operation
Operation of compressor is based on instructed frequency, continuously from indoor unit´s microcomputer after performing
temperature sampling and judgment.
There are total 30 different frequency values, which listed as Table on Frequency Number, to be instructed based on the
temperature judgment
No.
E9CKP
1
12.0
2
15.0
3
18.0
4
21.0
5
23.0
6
25.0
7
26.0
8
30.0
9
33.0
10
35.0
11
36.0
12
38.0
13
39.0
14
40.0
15
47.0
16
49.0
17
56.0
18
58.0
19
63.0
20
66.0
21
70.0
22
73.0
23
77.0
24
80.0
25
83.0
26
86.0
27
87.0
28
88.0
29
89.0
30
90.0
For normal start of operation, including Thermo-OFF, Deice-Resuming, and remote controller ON-OFF starts, the compressor
starts to operate at frequency no. 8, values of 30Hz and 32Hz for E9CKP and E12CKP respectively, for 60 seconds.
The frequency to be judged and instructed, however, starts to judge once the air conditioner operated and the judgment will
continue every 30 seconds until it is stopped by all kinds of compressor off conditions. This judgment is based on the internal
temperature sampling that involving internal setting temperature and intake air temperature.
From the internal sampling, the temperature different (intake air temperature - internal setting temperature) will be used to judge
the Zone on which the frequency to be instructed for the initial operation of compressor (refer to Table on Initial Frequency Zone).
Temperature, X (°C)
(Intake Air - Internal Setting)
X
-2.5
-2.5
X
-1.5
X
-1.0
X
-0.5
X
+0.5
X
+1.0
X
+1.5
X
X
+2.5
After the initial operation, the instructed frequency will change or shift from initial frequency according to the judgment on
temperature different from sampling (refer to the Table on Shifting Frequency Zone).
Table on Frequency Number
Frequency (Hz)
E12CKP
12.0
15.0
18.0
21.0
23.0
25.0
28.0
32.0
36.0
40.0
44.0
48.0
52.0
57.0
62.0
67.0
68.5
72.0
76.0
80.0
85.0
88.0
91.0
94.0
98.0
102.0
104.0
106.0
108.0
110.0
Table on Initial Frequency Zone
Zone
0
-1.5
1
-1.0
2
-0.5
3
+1.0
4
+1.0
5
+1.5
6
+2.5
7
8
Freq. MIN
Fc
Fc max. (E9CKP)
Fc max. (E12CKP)
Fh
Fh max.
Freq. No. - E9CKP
Cooling
Soft Dry
Heating
1
4
1
4
1
4
1
4
4
4
6
6
9
7
15
7
15
7
www.ilmalämpöpumput.com
18
Remarks
Freq. No. - E12CKP
Cooling
Soft Dry
30
1
4
30
1
4
10
1
4
7
1
4
4
4
4
1
6
6
1
9
8
1
16
8
1
16
8
Heating
30
30
10
7
4
1
1
1
1