Temperature, X (°C)
(Intake Air - Internal Setting)
X
-2.5
-2.5
X
-1.5
X
-1.0
X
-0.5
X
+0.5
X
+1.0
X
+1.5
X
X
+2.5
Besides, the range of operation frequency will change according to the setting environment as listed below:
Condition:
Cooling Mode
- if remote controller set
Hi
- if remote controller set
Me-, Me, Me+, Auto
- if remote controller set
Lo
- if Powerful Mode ON
Soft Dry Mode
Heating Mode
- if remote controller set
Hi
- if remote control set
Me-, Me, Me+, Auto
- if remote controller set
Lo
- if Powerful Mode ON
Remark:
(a)
If frequency decreases from MAX, the following frequency performed will be depending to outdoor temperature, as given in below table
(for 30 seconds only) and then continues as normal rule.
Outdoor Temperature, X (°C)
(b)
(If frequency increases from Freq. No. 17, the following frequency performed is as below (for 30 seconds only) and then continue as
normal rule.
Outdoor Temperature, X (°C)
(c)
When temperature different (intake - setting) < -1.0 °C or Thermo-Off activated and only valid for 120 seconds; not applicable during Soft
Dry Mode, and Anti-freezing control.
(d)
When temperature different (intake - setting) > +1.5 °C or Thermo-Off activated and only valid for 130 seconds.
Table on Shifting Frequency Zone
Zone
0
-1.5
1
-1.0
2
-0.5
3
+1.0
4
+1.0
5
+1.5
6
+2.5
7
8
28°C & fan speed =
28°C & fan speed =
28°C & fan speed =
18°C & fan speed =
18°C & fan speed =
18°C & fan speed =
X
30
X
30
X
10
X
X
10
X
4
www.ilmalämpöpumput.com
Frequency No. Shifting:
Cooling Mode / Soft Dry Mode
Shift to Freq. MIN
Shift to Freq. MIN
-2 Freq. No.
-1 Freq. No.
Same Freq. No.
+1 Freq. No.
+2 Freq. No.
Shift to Freq. MAX
Shift to Freq. MAX
Freq. no. for E9CKP
MIN
MAX
1
15
7
15
5
15
4
15
7
15
4
7
1
30
10
30
9
30
8
30
10
30
19
CS-E9CKP CU-E9CKP5 / CS-E12CKP CU-E12CKP5
Heating Mode
Shift to Freq. MAX
Shift to Freq. MAX
+2 Freq. No.
+1 Freq. No.
Same Freq. No.
-1 Freq. No.
-2 Freq. No.
Shift to Freq. MIN
Shift to Freq. MIN
Freq. no. for E12CKP
MIN
MAX
1
16
7
16
6
16
5
16
7
16
4
8
1
30
10
30
9
30
8
30
10
30
Frequency No.
13
7
Frequency No.
10
13
17
Remarks
(a)
(a), (c)
(a), (c)
(a), (c)
(a), (c)
(b)
(b), (d)
(b), (d)
(b), (d)
(b), (d)