Toshiba e-Studio3511 Service Handbook page 55

Toshiba e-studio multifunctional digital color systems
Hide thumbs Also See for e-Studio3511:
Table of Contents

Advertisement

Notes:
1. The digit after the hyphen in "Code" of the following table is a sub code.
2. In "RAM", the NVRAM of the board in which the data of each code is stored is indicated. "M" stands for
the LGC board and "SYS" stands for the SYS board.
Classifi-
Code
cation
200
Devel-
Initialization of
opment
color auto-toner
201
sensor light
amount correction
202
target value
203
204
206
207
Devel-
Initialization of color auto-
opment
toner sensor light amount
correction target value
208
Devel-
Enforced correction of color
opment
auto-toner sensor light
amount
210
Transfer
1st transfer roller bias output
adjustment
(When not transferred)
211-0
Transfer
1st transfer roller
bias output
211-1
adjustment
(Image quality
211-2
control test
pattern)
211-3
212
Transfer
1st transfer roller
bias output
adjustment
214
215
216
217
November 2003 © TOSHIBA TEC
Adjustment mode (05)
Default
Func-
Items
<Acceptable
tion
value>
All
ALL
(Y,M,C,K)
<0-255>
Y
ALL
<0-255>
M
ALL
<0-255>
C
ALL
<0-255>
K
ALL
<0-255>
YMC
ALL
<0-255>
ALL
(color)
ALL
(color)
ALL
<0-225>
Y
ALL
(color)
<0-225>
M
ALL
(color)
<0-225>
C
ALL
(color)
<0-225>
K
ALL
(color)
<0-225>
Plain
ALL
paper
(black)
<0-225>
Thick
ALL
paper 1
(black)
<0-225>
Thick
ALL
paper 2
(black)
<0-225>
Thick
ALL
paper 3
(black)
<0-225>
OHP film
ALL
(black)
<0-225>
2 - 35
04/05
RAM
Contents
-
M
The value starts changing approx. 3
minutes after this adjustment started.
-
M
The value is automatically set during
this adjustment (approx. 2 minutes).
-
M
(As the value increases, the sensor
-
M
output increases correspondingly.)
(
Chapter 3.2)
-
M
-
M
-
M
Initializes the color auto-toner sensor
light amount correction target value.
-
M
Performs the color auto-toner sensor
light amount correction forcibly.
225
M
When the value decreases, the 1st
transfer roller bias output increases.
The adjustment value becomes
effective when the Setting Mode (08-
541, 549 and 551) is 0 (invalid).
140
M
When the value decreases, the 1st
transfer roller bias output increases.
140
M
The adjustment value becomes
effective when the Setting Mode (08-
140
M
541, 549 and 551) is 0 (invalid).
148
M
135
M
When the value decreases, the 1st
transfer roller bias output increases.
The adjustment value becomes
135
M
effective when the Setting Mode (08-
541, 549 and 551) is 0 (invalid).
135
M
135
M
135
M
e-STUDIO3511/4511 ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
5
5
5
5
5
5
6
6
3
14
14
14
14
3
3
3
3
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio4511

Table of Contents