2. Specification

Model
Performance Test Condition
Power Supply
Capacity
Running Current
Input Power
Annual Consumption
EER
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Capacity
Running Current
Input Power
COP
Power Factor
Indoor Noise (H / L / QLo)
Outdoor Noise (H / L / QLo)
Low Temp. : Capacity (kW) / I.Power (W) / COP
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
Max Current (A) / Max Input Power (W)
Starting Current (A)
Type
Compressor
Motor Type
Output Power
Indoor
Outdoor
Phase, Hz
V
kW
BTU/h
kcal/h
A
W
kWh
W/W
BTU/hW
kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
kW
BTU/h
kcal/h
A
W
W/W
BTU/hW
kcal/hW
%
dB-A
Power Level dB
dB-A
Power Level dB
W
CS-HE9NKE CS-AE9NKE
CU-HE9NKE CU-AE9NKE
EUROVENT
Single, 50
Min.
0.85
2900
730
170
5.00
17.06
4.29
39 / 26 / 23
55 / 42 / 39
46 / - / -
61 / - / -
0.85
2900
730
165
5.15
17.58
4.42
42 / 27 / 24
58 / 43 / 40
47 / - / -
62 / - / -
4.71 / 1.50k / 3.14
3.92 / 1.46k / 2.68
8.0 / 1.72k
Rotary Motor
Brushless (4 poles)
5
230
Mid.
2.50
8530
2150
2.2
455
228
5.49
18.75
4.73
90
3.20
10900
2750
2.7
575
5.57
18.96
4.78
93
2.7
900
Max.
3.00
10200
2580
670
4.48
15.22
3.85
6.50
22200
5590
1.70k
3.82
13.06
3.29