12.12.1.2
Judge Sunlight Intensity
Based on sunlight sensor output voltage, the sunlight intensity value will be computed and logged to sunlight
intensity database.
The sunlight sensor sensitivity could be adjusted:
SET
Remote control normal mode
Press and release within 10s
Default: (Battery insert)
Set to Level. 3
Other than default
Display last set data
Set to level 4
Set to level 5
Set to level 1
Set to level 2
Security Level 1: Less sensitive to sunlight intensity
Security Level 3: Default sensitivity level
Security Level 5: More sensitive to sunlight intensity
Press
Transmit
Timer
solar radiation
SET
level
&
after *2 secs
go back to
normal mode