Perkins 1104D-E44T Operation And Maintenance Manual page 53

Industrial engines
Table of Contents

Advertisement

SEBU9066
• After the engine has stopped, wait for 60 seconds
in order to allow the fuel pressure to be purged
from the high-pressure fuel lines before any
service or repair is performed on the engine fuel
lines. If necessary, perform minor adjustments.
Repair any leaks from the low-pressure fuel
system and from the cooling, lubrication, or air
systems. Replace any high-pressure fuel line that
has leaked. Refer to Disassembly and assembly
Manual, "Fuel Injection Lines - Install".
• Check the crankcase oil level. Maintain the oil level
between the "MIN" mark and the "MAX" mark on
the engine oil level gauge.
• If the engine is equipped with a service hour meter,
note the reading. Perform the maintenance that is
in the Operation and Maintenance Manual,
"Maintenance Interval Schedule".
• Fill the fuel tank, in order to help prevent
accumulation of moisture in the fuel. Do not overfill
the fuel tank.
NOTICE
Only use antifreeze/coolant mixtures recommended
in this Operation and Maintenance Manual, "Refill Ca-
pacities and Recommendations" topic or in this Oper-
ation
and
Maintenance
Recommendations" topic. Failure to do so can cause
engine damage.
Pressurized System: Hot coolant can cause seri-
ous burns. To open the cooling system filler cap,
stop the engine and wait until the cooling system
components are cool. Loosen the cooling system
pressure cap slowly in order to relieve the
pressure.
• Allow the engine to cool. Check the coolant level.
• Check the coolant for correct antifreeze protection
and the correct corrosion protection. Add the
correct coolant/water mixture, if necessary.
• Perform all required periodic maintenance on all
driven equipment. This maintenance is outlined in
the instructions from the OEM.
Manual,
"Fluid
53
Engine Stopping
After Stopping Engine

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1104d-e44ta

Table of Contents