Parameter list
Function Parameters
549
Protocol selection
NET mode operation command
550
source selection
PU mode operation command source
551
selection
553
PID deviation limit
554
PID signal operation selection
555
Current average time
556
Data output mask time
Current average value monitor signal
557
output reference current
563
Energization time carrying-over times
564
Operating time carrying-over times
570
Multiple rating setting
571
Holding time at a start
573
4mA input check selection
575
Output interruption detection time
576
Output interruption detection level
577
Output interruption cancel level
578
Auxiliary motor operation selection
579
Motor connection function selection
580
MC switching interlock time
581
Start waiting time
Auxiliary motor connection-time
582
deceleration time
Auxiliary motor disconnection-time
583
acceleration time
584
Auxiliary motor 1 starting frequency
585
Auxiliary motor 2 starting frequency
586
Auxiliary motor 3 starting frequency
587
Auxiliary motor 1 stopping frequency
588
Auxiliary motor 2 stopping frequency
589
Auxiliary motor 3 stopping frequency
590
Auxiliary motor start detection time
591
Auxiliary motor stop detection time
611
Acceleration time at a restart
653
Speed smoothing control
654
Speed smoothing cutoff frequency
799
Pulse increment setting for output
power
867
AM output filter
869
Current output filter
872
Input phase loss protection selection
68
Name
0, 1
0, 1, 9999
1, 2
0 to 100.0%, 9999
0 to 3, 10 to 13
0.1 to 1.0s
0.0 to 20.0s
0 to 500A/0 to 3600A
(0 to 65535)
(0 to 65535)
0, 1
0.0 to 10.0s, 9999
1, 9999
0 to 3600s, 9999
0 to 400Hz
900 to 1100%
0 to 3
0 to 3
0 to 100s
0 to 100s
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 400Hz
0 to 3600s
0 to 3600s
0 to 3600s, 9999
0 to 200%
0 to 120Hz
0.1kWh, 1kWh, 10kWh,
100kWh, 1000kWh
0 to 5s
0 to 5s
0, 1
Minimum
Setting Range
Setting
Increments
0.1%
0.1s
0.1s
0.01/0.1A
0.1s
0.1s
0.01Hz
0.1%
0.1s
0.1s
0.1/0.01s
0.1/0.01s
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
0.1s
0.1s
0.1s
0.1%
0.01Hz
0.1
0.01s
0.01s
Refer
Initial
to
Value
Page
1
1
213
1
9999
190
1
2
190
9999
225
1
0
225
1s
259
0s
259
Rated
inverter
259
current
1
0
132
1
0
132
1
0
81
9999
98
1
9999
173
1s
225
0Hz
225
1000%
225
1
0
242
1
0
242
1s
242
1s
242
1s
242
1s
242
60Hz
242
60Hz
242
60Hz
242
0Hz
242
0Hz
242
0Hz
242
5s
242
5s
242
5/15s
142
0
160
20Hz
160
1kWh
130
0.01s
137
0.02s
137
1
0
152
Customer
Setting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents