4.11.2 DU/PU monitor display selection

(Pr. 52, Pr. 54, Pr. 158, Pr. 170, Pr. 171, Pr. 268, Pr. 563, Pr. 564, Pr. 891)
The monitor to be displayed on the main screen of the operation panel (FR-DU07)/parameter unit (FR-PU04/FR-
PU07) can be selected.
Parameter
Name
Number
DU/PU main display data
52
selection
CA terminal function
54
selection
AM terminal function
158
selection
170
Watt-hour meter clear
171
Operation hour meter clear
Monitor decimal digits
268 *
selection
Energization time
563
carrying-over times
Operating time carrying-
564
over times
Cumulative power monitor
891
digit shifted times
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 179)
* The above parameters allow its setting to be changed during operation in any operation mode even if "0" (initial value) is set in
Pr. 77 Parameter write selection.
(1) Monitor description list (Pr. 52)
⋅ Set the monitor to be displayed on the operation panel (FR-DU07) and parameter unit (FR-PU04/FR-PU07) in Pr.
52 DU/PU main display data selection.
⋅ Set the monitor to be output to the terminal CA (analog output (0 to 20mADC current output)) in Pr. 54 CA terminal
function selection.
⋅ Set the monitor to be output to the terminal AM (analog output (0 to 10VDC voltage output)) in Pr. 158 AM terminal
function selection.
⋅ Refer to the following table and set the monitor to be displayed. (The signals marked × cannot be selected for
monitoring)
Types of Monitor
Increments
Output frequency
0.01Hz
0.01A/0.1A
Output current
Output voltage
0.1V
Fault display
Frequency setting
0.01Hz
value
132
Initial Value
0
(output
frequency)
1
(output
frequency)
9999
9999
9999
0
0
9999
Pr. 52 Parameter
Setting Value
PU main
DU LED
monitor
0/100
0/100
*5
0/100
0/100
5
*1
Setting Range
0, 5, 6, 8 to 14,
Select the monitor to be displayed on the
17, 20, 23 to 25,
operation panel and parameter unit.
50 to 57, 100
Refer to the following table for monitor description.
Select the monitor output to terminal CA.
1 to 3, 5, 6, 8 to
14, 17, 21, 24,
50, 52, 53
Select the monitor output to terminal AM.
0
Set "0" to clear the watt-hour meter monitor.
Set the maximum value when monitoring from
10
communication to 0 to 9999kWh.
Set the maximum value when monitoring from
9999
communication to 0 to 65535kWh.
Set "0" to clear the operation time monitor.
0, 9999
Setting "9999" has no effect.
0
Displayed as integral value.
1
Displayed in 0.1 increments.
9999
No function
0 to 65535
Displays the numbers of cumulative energization
(reading only)
time monitor exceeded 65535h. Reading only
0 to 65535
Displays the numbers of operation time monitor
(reading only)
exceeded 65535h. Reading only
Set the number of times to shift the cumulative
0 to 4
power monitor digit.
Clamps the monitor value at maximum.
No shift
9999
Clears the monitor value when it exceeds the
maximum value.
Pr. 54 (CA)
Full-scale
Pr. 158 (AM)
value of the
Parameter
terminal CA
Setting
and AM
Value
1
Pr. 55
2
Pr. 56
200V class:
400V
3
400V class:
800V
×
5
Pr. 55
Description
Description
Displays the inverter output frequency
Displays the inverter output current
effective value
Displays the inverter output voltage
Displays 8 past faults individually
Displays the set frequency