Sylvania 6842PE Service Manual page 75

Hide thumbs Also See for 6842PE:
Table of Contents

Advertisement

B. Disassebmly of Main PSU and Sub PSU
1) Main PSU
1. Discharge all the charges which may remain in capacitors of PSU.
2. Disconnect all connectors between Main PSU and other Board as shown above.
3. Unscrew all screws of Main PSU and remove it.
Reassembly Notes:
When re-installing main PSU, perform the following procedures.
1. Screw all screws of Main PSU.
2. Connect Power Input Cable to CN8001.
3. Connect a cable from CN8008 of Main PSU to CN803 of LM.
4. Turn on the power of PSU.
5. Check and adjust each voltages at Test Points. (refer to "How to adjust Voltages of PSU" below)
6. If all voltages are OK, then turn the power off.
7. Connect all connectors between Main PSU and other Boards.
2) How to adjust voltages of PSU
< Positions of Volumes for Voltage Adjustments and Test Point >
1. Measure the voltage at each Test Point.
2. Adjust the level until it reaches same voltage value as written on the VOLTAGE LABEL of PDP Module.
3) Sub PSU
1. Discharge all the charges which may remain in capacitors of PSU.
2. Disconnect all connectors between Sub PSU and other Board.
3. Unscrew all screws of Sub PSU and remove it.
CN8003
Sub PSU
CN9005
CN8005
CN9007
CN8004
CN8007
CN9006
Vs
Vs
Vsc
Va
Vset
Vset
Vsc
: Test point
CN8002
CN8009
Main PSU
CN8001
CN8008
Ve
Ve
Va
: Volume
2-1-9
L0604DCP

Hide quick links:

Advertisement

Table of Contents
loading