LX Series Direct Vent Gas Fireplace
LIGhtING pILot FoR the FIRSt tIMe
AppRoVeD LeAK teStING MethoD
You may check for gas leaks with the following
methods only:
•
Soap and water solution
•
An approved leak testing spray
•
Electronic sniffer
Never check for gas leak
with open flame!
Check for gas leaks in each of the following locations:
•
Pipe from the gas supply line connection to the gas valve
•
Burner connections
•
Pilot
•
Each joint or connection
1. Depress and turn knob counterclockwise
pilot position.
2. Depress fully and hold pilot gas knob. Depress piezo
ignitor as many times as needed to ignite the pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
34
•
Field made joints / gas shutoff valve
•
Factory made joints
•
All joints on valve and control body
LIGhtING pILot
to
opeRAtING INStRuctIoNS
If using a soap and water solution
to test for leaks, Do Not spray
solution onto control body.
Note: Remove any excessive pipe
compound from the connections.
excessive pipe compound can set off
electronic sniffers.
P I L
O T
Figure 49 -
Pilot Position
FP1935
control knob pilot
51D0528