Basic Control Usage; Comfortlink Control; Scrolling Marquee - Carrier 48AJ Operating And Service Manual

Single package large rooftop units with scroll compressors and comfort link version 4.x controls
Table of Contents

Advertisement

Table 1 — A Series Product Line
UNIT
48AJ
CV Unit with Gas Heat, Vertical Supply
48AK
VAV Units with Gas Heat, Vertical Supply
48AW
CV Unit with Gas Heat, Horizontal Supply
48AY
VAV Unit with Gas Heat, Horizontal Supply
50AJ
CV Unit with Optional Electric Heat, Vertical Supply
50AK
VAV Units with Optional Electric Heat, Vertical Supply
50AW
CV Unit with Optional Electric Heat, Horizontal Supply
50AY
VAV Unit with Optional Electric Heat, Horizontal Supply
LEGEND
CV
— Constant Volume
VAV — Variable Air Volume
The A Series units provide ventilation, cooling, and heating
(when equipped) in variable air volume (VAV), variable volume
and temperature (VVT®), and constant volume (CV) applica-
tions. The 48AJ,AK,AW,AY and 50AJ,AK,AW,AY units con-
tain the factory-installed ComfortLink™ control system which
provides full system management. The main base board (MBB)
stores hundreds of unit configuration settings and 8 time of day
schedules. The MBB also performs self diagnostic tests at unit
start-up, monitors the operation of the unit, and provides alarms
and alert information. The system also contains other optional
boards that are connected to the MBB through the Local Equip-
ment Network (LEN). Information on system operation and
status are sent to the MBB processor by various sensors and
optional boards that are located at the unit. Access to the unit
controls for configuration, set point selection, schedule
creation, and service can be done through a unit-mounted
Scrolling Marquee. Access can also be done through the Carrier
Comfort Network
system using the ComfortVIEW™
®
software or the accessory Navigator™ hand-held display.
The ComfortLink system controls all aspects of the rooftop.
It controls the supply-fan motor, compressors, and economizers
to maintain the proper temperature conditions. The controls also
cycle condenser fans to maintain suitable head pressure. All
VAV units are equipped with a standard VFD (variable frequen-
cy drive) for supply fan speed control and supply duct pressure
control. The ComfortLink control directly controls the speed of
the VFD based on a static pressure sensor input. In addition, the
ComfortLink control can control the building pressure using
multiple power exhaust fans controlled from damper position or
from a building pressure sensor. The control safeties are contin-
uously monitored to prevent the unit from operating under ab-
normal conditions. Sensors include suction pressure transducers
and saturated condensing temperature sensors which allow for
display of operational pressures and saturation temperatures.
A scheduling function, programmed by the user, controls
the unit occupied/unoccupied schedule. Up to 8 different
schedules can be programmed.
The controls also allow the service person to operate a quick
test so that all the controlled components can be checked for
proper operation.

BASIC CONTROL USAGE

ComfortLink Control —
comprehensive unit-management system. The control system
is easy to access, configure, diagnose and troubleshoot.
The control is flexible, providing two types of constant
volume cooling control sequences, two variable air volume
cooling control sequences, and heating control sequences for
two-stage electric and gas systems, and for multiple-stage gas
heating, in both Occupied and Unoccupied schedule modes.
This control also manages:
• VAV duct pressure (through optional VFD), with reset
• Building pressure through two different power exhaust
systems
APPLICATION
The ComfortLink control is a
• Condenser fan cycling for mild ambient head pressure
control
• Space ventilation control, in Occupied and Unoccupied
periods, using CO
2
tilation defined by damper position
• Smoke control functions
• Occupancy schedules
• Occupancy or start/stop sequences based on third party
signals
• Alarm status and history and run time data
• Management of a complete unit service test sequence
System diagnostics are enhanced by the use of multiple
external sensors for air temperatures, air pressures, refrigerant
temperatures, and refrigerant pressures. Unit-mounted actua-
tors provide digital feedback data to the unit control.
The ComfortLink control is fully communicating and
cable-ready for connection to the Carrier Comfort Network
(CCN) building management system. The control provides
high-speed communications for remote monitoring via the
Internet. Multiple units can be linked together (and to other
ComfortLink control equipped units) using a 3-wire communi-
cation bus.
The ComfortLink control system is easy to access through
the use of a unit-mounted display module. There is no need to
bring a separate computer to this unit for start-up. Access to
control menus is simplified by the ability to quickly select from
11 menus. A scrolling readout provides detailed explanations
of control information. Only four, large, easy-to-use buttons are
required to maneuver through the entire controls menu.
For added service flexibility, an accessory hand-held
Navigator module is also available. This portable device has an
extended communication cable that can be plugged into the
unit's communication network either at the main control box or
at the opposite end of the unit, at a remote modular plug. The
Navigator display provides the same menu structure, control
access and display data as is available at the unit-mounted
Scrolling Marquee display.
Scrolling Marquee —
face used to access the control information, read sensor values,
and test the unit. The Scrolling Marquee is located in the main
control box and is standard on all units. The Scrolling Marquee
display is a 4-key, 4-character, 16-segment LED display
module. The display also contains an Alarm Status LED (light-
emitting diode). See Fig. 1. The display is easy to operate using
4 buttons and a group of 11 LEDs that indicate the following
menu structures (see Appendix A):
• Run Status
• Service Test
• Temperatures
• Pressures
• Set points
• Inputs
• Outputs
• Configuration
• Timeclock
• Operating Modes
• Alarms
Through the Scrolling Marquee, the user can access all of
the inputs and outputs to check on their values and status, con-
figure operating parameters plus evaluate the current decision
status for operating modes. Because the A-Series units are
equipped with suction pressure and saturated condensing
temperature thermistors, the Scrolling Marquee can also
display refrigerant circuit pressures typically obtained from
service gages. The control also includes an alarm history which
can be accessed from the display. In addition, through the
Scrolling Marquee, the user can access a built-in test routine
that can be used at start-up commissioning to diagnose opera-
tional problems with the unit.