Installation and connection

Connect the Cables to the Base

Connect the coaxial cables and power supply cable to the terminals within the Base.
• Turn OFF the power supply to all compornents before making connections.
Fold back the net and insulate so that a short cir-
cuit does not occur from the net coming apart.
Net
Polyethylene
Core line
Insulation tape
12mm
5mm
15
3
(
/
"
)
(
/
"
)
32
16
DC 12 V or AC 24 V
Power Supply cable
Power Supply
terminal
Coaxial
cable
processing
terminal
Coaxial cable
Conductor diameter (mm)
Maximum
extension (m)
• If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur
when the unit is at its maximum power consumption. Either use a thick cable to restrict
the voltage drop at the camera side to below 10%, or place the power supply near to
the camera. If voltage drop occurs during operation, the performance will be unstable.
• Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
• When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
• The AC 24 V power supply should conform to the following:
U-type:
Class 2 only
E-type:
Isolated power supply only
E-12
Video signal cables
Connect the coaxial cables to the coaxial
cable processing terminal.
CAUTION
• Use the RG-59 or RG-6 video signal
cable (coaxial cable).
• If RG-11 is used, the cable cannot be
directly connected to the terminal. Connect
the RG-6 coaxial cable to the terminal and
link to the RG-11 coaxial cable.
• Perform the process shown on the left
diagram (above illustration) for the coaxial
cable tip before connecting.
DC 12 V or AC 24 V power supply cable
Connect a DC 12V or AC 24V power supply
cable to the power supply terminal. To pre-
vent connection errors or a cable disconnec-
tion, we recommend the use of lug plates for
the connections.
The following table shows the connection dis-
tances and connection cables provided that
2-conductor VVF cables (vinyl-insulated vi-
nyl sheath cables) are used.
1.0mm
1.6mm
ø
ø
(AWG18) (AWG14) (AWG12)
DC 12V
60m
160m
(200ft)
(520ft)
AC 24V
150m
400m
(490ft)
(1300ft)
Do not cross the power supply cable and
coaxial cable.
CAUTION

Mount the Camera unit to the Base

Fill the conduit hole and mounting holes with sealing agent and insert the silica gel before
mounting the camera unit to the base.
Sealing agent
Silica gel
2.0mm
ø
250m
(820ft)
600m
(2000ft)
Fill using sealing agent
Completely fill the conduit hole using sealing
Sealing
agent. Also fill the mounting holes when not
agent
in use.
MEMO
The sealant should be GE silicone or
equal.
Not filling the holes completely with seal-
Lug plate
ing agent may cause moisture to enter,
clouding the lens and dome cover as a
result. Be sure to completely close the
holes.
Insert the included Silica gel
Insert the provided silica gel in the Base inte-
rior and hold using the lug plate.
MEMO
Always replace the silica gel when recon-
necting/resetting during repair or mainte-
nance.
When replacing, use:
Service parts No. LW40500-001A
• When performing installation under
raining conditions, take caution as not
to allow rain to enter inside the unit.
• Always use the provided silica gel. When
not using the silica gel, the dome cover
of the camera lens may cloud as a result.
• If the camera angle is not adjusted at
installation, insert the silica gel inside
the unit after adjustment. The effects of
the gel diminish with prolonged
exposure to air.
Mount the camera unit to the base
Align
and
on the base.
CAUTION
CAUTION
on the camera with
and
E-13