Setting an indoor unit address and installation option
A
•  W hen"A"~"F"isenteredtoSEG4~6,theindoorunitMAINADDRESSisnotchanged.
•  I fyousettheSEG3as0,theindoorunitwillmaintainthepreviousMAINADDRESSevenifyouinputtheoptionvalueofSEG4~6.
•  I fyousettheSEG9as0,theindoorunitwillmaintainpreviousRMCADDRESSevenifyouinputtheoptionvalueofSEG11~12.
5. The MAIN address is for commnication between the indoor unit and the outdoor unit. Therefore, you must set it to
operate the air conditioner properly.
Setting an indoor unit installation option (suitable for the condition of each installation location)
1. Check whether power is supplied or not.
- When the indoor unit is not plugged in, there should be additional power
supply in the indoor unit.
2. The panel(display ) should be connected to an indoor unit to receive option.
3. Before installing the indoor unit, assign an option to the indoor unit according
to the air conditioning system plan.
- The default setting of an indoor unit installation option is "02000-100000-200000-300000".
- Individual control of a remote controller(SEG20) is The function that controls an indoor unit individually when there is
more than one indoor unit.
4. Set the indoor unit option by wireless remote controller.
- When entering Address option, connect remote controller receiver.
Option
SEG1
Explanation
PAGE
Indication Details Indication
Indication and Details
Option
SEG7
Explanation
PAGE
Indication Details Indication
Indication and Details
Option
SEG13
Explanation
PAGE
Indication Details Indication
Indication and Details
Option
SEG19
Explanation
PAGE
Indication Details Indication
Indication and Details
▶ If you input a number other than 0~4 of the individual control of the indoor unit(SEG20), the indoor is set as "indoor 1".
30
SEG2
MODE
Details
0
2
SEG8
Details
1
0
SEG14
External control
Details
0
No use
2
1
On/Off control
2
Off control
SEG20
Details
3
0
SEG3
SEG4
Indication
Details
Indication
0
SEG9
SEG10
Indication
Details
Indication
0
SEG15
SEG16
External control output
Indication
Details
Indication
0
Thermo ON
1
Operation ON
SEG21
SEG22
Indication
Details
Indication
0
Indoor Unit
1(L)
2(N)
SEG5
Central control
Details
Indication
Details
0
No use
0
1
Use
SEG11
Details
Indication
Details
0
0
SEG17
Buzzer
Details
Indication
Details
0
Use
0
1
No Use
SEG23
Details
Indication
Details
0
0
F2
F1
SEG6
Indication Details
0
SEG12
Master / Slave
Indication Details
0
Master
1
Slave
SEG18
Indication Details
0
SEG24
Indication Details
0