CHAPTER 2. OfficeServ 7400 Hardware
No.
Component
1
Ground Lug
2
Connector for External Rectifier
3
Handle
4
Fuse Holder
5
AC LED
6
DC LED
7
Battery Socket
8
Power I/O Connector
9
Power Switch
10
Battery Switch

2.2.1 Configuration of Slots

The basic chassis and expansion chassis each have 12 slots in which modules can be
mounted. The modules mounted depend on the configuration of the OfficeServ 7400 (see
Table 2.2).
Chassis
Basic Chassis
(OfficeServ Access)
Expansion Chassis
(OfficeServ Expansion)
If using the total capacity of TEPRI2 and MGI64, a basic chassis that supports 64 channels
per slot is used.
2-4

Table 2.1 Rear Panel of OfficeServ 7400 Basic Chassis

Lug for grounding system communication
To supply external power for PoE (Power over Ethernet)
To use while mounting/removing a power module
Fuse for AC input power
The LED turns on while applying AC power.
The LED turns on while the DC power is operating.
Socket to connect an external battery
Connector for power cable
System power switch
Switch to supply battery power to the OfficeServ 7400 or
charge the battery.

Table 2.2 Mountable Modules

Slots
Slot 0
Slot 3
Slot 1 and 2
Slot 4~11
Slot 0
Slot 1~11
Blank Module
A Blank Module is a dummy module that functions as a screen to prevent ingress
of unwanted material into a slot when it is not being used.
Function
Mountable Modules
LP40
MP40
All Modules except MP40 and LP40
LP40
All Modules except MP40 and LP40
© Samsung Business Communications