Drain Pump; Motor - Electrolux EWM 1000 AEG Service Manual

Toploader
Table of Contents

Advertisement

Drain pump

The drain pump is directly controlled via triac from the control electronics.

Motor

The motor is directly phase-controlled via triac from the control electronics.
Relays K2, K3 are responsible for commuting the sense of rotation.
Field switching (if any) is controlled by relay K4.
Speed is monitored by tachometer generator g1 and controlled by control electronics.
Integral overheat protection disconnects the motor from power supply at 115°C.
Connection:
Safety
-
If the triac for the motor is in short-circuit, or if the tachometer generator is interrupted, 4 trials are
executed in intervals of 1 minute each.
After a break of 20 minutes, the fifth and last trial is started. If the motor does not run this time, the
programme is aborted.
(see Page Service-Program fault display E60)
DGS-TDS-N 11.06 R.B.
© Electrolux
- 15 -
599 51 50 25
EN