Awb Adjustment (Awb In The Calibration Section) - Minolta Dimage XT Repair Manual

Hide thumbs Also See for Dimage XT:
Table of Contents

Advertisement

AWB Adjustment (AWB in the Calibration section)

This adjustment creates the compensation data for WB output against color temperature of the light
source.
Whenever after replacing the CP-1 Compl PWB (#0408), the PW-1 Compl PWB (#0432,0452), the ST-1
Compl PWB (#0406) or the Lens Assy (#3255-0600), be sure to perform the adjustment.
Perform this adjustment in darkroom.
Equipment Required
PC (IBM PC/AT Compatible Computer with the F/X Series Adjustment Program is installed)
USB cable USB-500
AC Adapter AC-6
Color Viewer LV-1450DC
Preparation
Perform the adjustment 30 minutes or longer after turning on the Color Viewer.
The Color Viewer should be checked and adjusted according to its maintenance instruction on page 23
in 2783 repair guide.
Adjustment
1. Turn the mode dial to Auto-recording position.
2. Press the down key (w) to set the lens to the wideangle.
3. Set the camera and Color Viewer as illustrated in Fig 1.
4. Connect the camera to the computer with the USB cable USB-500, and start Adjustment Program
(DscCalDi.exe).
5. Click "AWB" in the adjustment screen.
"Execute AWB&AGC Gain Calibration. Yes or No" appears on the screen.
6. Click "Yes".
The camera performs adjustment, then the AWB adjustment value is displayed on the screen.
7. Click "OK" on the screen to return to the adjustment screen.
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Fig. 1
Camera
Camera
Camera
Camera
Camera
Color Viewer LV-1450DC
Color Viewer LV-1450DC
Color Viewer LV-1450DC
Color Viewer LV-1450DC
Color Viewer LV-1450DC