7. Overall Noise Level Check
Mode
Camera recording and playback
Signal
No signal: Insert a shorting plug in the
MIC jack
Measurement Point
Audio output terminal left or right
Measuring Instrument
Audio level meter
Specified Value
Below –45dBs
(IHF-A filter ON, 20kHz LPF ON)
Checking Method:
1) Insert a shorting plug in the MIC jack.
2) Record in the camera mode.
3) Playback the recorded section.
4) Check that the noise level is the specified value.
8. Overall Separation Check
Mode
Camera recording and playback
Signal
400Hz, –66dBs signal: MIC jack
<right> [left]
(Connect the MIC jack <left> [right]
to GND)
Measurement Point
Audio output terminal <left> [right]
Measuring Instrument
Audio level meter
Specified Value
Below –40dBs
< > : Left channel check
[ ] : Right channel check
Checking Method:
1) Input the 400Hz, –66dBs signal in the <right> [left] terminal
of the MIC jack only.
2) Record in the camera mode.
3) Playback the recorded section.
4) Check that the signal level of the audio output <left> [right]
terminal is the specified value.