2. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note 1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Note 1: Dark Siemens star chart.
Switch setting:
1) NIGHT SHOT .................................................................. OFF
2) DIGITAL ZOOM (Menu display) ................................... OFF
3) STEADY SHOT (Menu display) ..................................... OFF
Preparation for adjustment
The minipattern box is installed as shown in the following figure.
Note : The attachment lenses are not used.
Minipattern box
Regulated power supply
Output current more than 3.5A
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Fig. 5-1-8.
Below 5 cm
Camcorder
Camera
table
11.29 ± 0.01Vdc
Need not connected
Adjusting method:
1) Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 5 cm.
2) Make the height of the minipattern box and the camcorder equal.
3) Check that the output voltage of the regulated power supply is
11.29 ± 0.01 Vdc.
4) Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
5) Select page: 0, address: 01, and set data: 01.
6) Check that the data of page: F, address:38 to 3D, 5A to 5E, F8
to FA is the initial value (See table below).
Address
Data
38
1C
39
03
3A
25
3B
24
3C
11
3D
05
5A
2A
7) Select page: 6, address: 02, and check that the data is "00".
8) Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
9) Select page: 6, address: 01, set data: 27, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
10) Select page: 6, address: 02, and check that the data is "01".
Processing after Completing Adjustments
1) Select page: 0, address:01, and set data: 00.
2) Turn OFF the main power supply (8.4V).
3) Perform "Flange Back Check".
5-22
Address
Data
5B
00
5C
19
5D
00
5E
37
F8
00
F9
00
FA
00