Troubleshooting - Quadra-Fire QFP 30 Operation & Maintenance Manual

Direct vent gas fireplace
Table of Contents

Advertisement

Pilot won't light
Is a gas shut-off valve turned on?
Is the valve control knob turned to "PILOT"
(See Lighting Instructions, #7, Pg. 34).
Is the valve control knob pushed in? (See Lighting
Instructions,)
Was the igniter pressed repeatedly? (See Lighting
Instructions.)
Main Burners Will Not Start
Has the pilot light gone out? (See Lighting Instruc-
tions,)
Is the gas control valve turned to "PILOT" or "OFF" ?
(See Lighting Instructions).
Is the ON/OFF switch in the "OFF" position? (Turn
to "ON")
Is the remote control working correctly?
(See instruction manual for the remote control).
Is the thermostat disconnected or set too low?
If LP, is the tank empty?
Remote Control Does Not Turn Unit On / Off
Has the pilot light gone out? (See Lighting Instructions.)
Is the gas control valve turned to "PILOT" or "OFF? (See
Lighting Instructions).
Is the ON/OFF switch turned to "OFF"? (Turn the switch
to "OFF")
If the switch is on, unit will remain on.
Is the remote too far away from the fireplace? (Use
remote closer to fireplace)
Is the remote control receiver turned "OFF"?
(See instruction manual for the remote control).
Are the remote control batteries dead?
(See instruction manual for the remote control).
Thermostat Does Not Work
Has the pilot light gone out? (See Lighting Instruc-
tions.)
Is the gas control valve turned to "PILOT" or "OFF" ?
(See Lighting Instructions).
Is the thermostat set too low? (See Thermostat
Operation.)
Is the On/OFF switch turned to "OFF? (Set the switch
to "ON")
If switch is on, unit will remain on. (The switch overrides
the thermostat.)
Fireplace Will Not Distribute Heat
Is the fireplace getting electricity? (Check the breaker
switch)
Is the fireplace up to temperature? (See Operating
Procedures.)
Is Blower operational? (Check Fan Speed control.)
Pilot Goes Out Once a Month or More
Has the gas supply been shut off? (Keep gas supply
turned on)
03/21/01 #250-6120
QFP 30 Direct Vent Gas Fireplace

TROUBLESHOOTING

Flames Are Too blue
Has the fireplace just been started? (This is normal -
see Initial Start-up.)
Primary Air adjustment--contact dealer.
Flames Are Too Short (Under 6")
Is the flame height may be turned too low? (Turn the flame
height to "HI"; see Adjusting the Flame Height.)
Primary air adjustment - Contact Dealer.
Damper adjusted properly? - Contact Dealer.
Thin Layer of Soot Covers the Glass
Are the logs or embers placed incorrectly? (See Log
Set Installation.)
Is the air shutter adjusted properly? (Contact Dealer for
Air Shutter adjustment)
Damper adjusted properly?