64
VL1500K5 ('05-MODEL)
ACTIVE CONTROL INSPECTION
1) Set up the SDS tool. (Refer to the SDS operation manual for
further details)
2) Turn the ignition switch ON.
3) Click "Decomp sol operating control" 1.
4) With the engine starter button pushed, click "On" button 2.
At this time, if an operation sound is heard from the decomp.
solenoid valve, the function is normal.
NOTE:
Decomp. solenoid valve can be operated about one second
after button is turned "On".