Continuous Flow Icemaker Installation Manual
D
C
RAIN
ONNECTION
1. Overflow Line—is a 3/8" I.D. flexible tube located at the rear of the unit. Extend this line to proper drain.
2. Condenser Outlet—is a 3/8" FPT located on the rear panel.
E
S
LECTRICAL
UPPLY
1. Power Access—is provided with a 7/8" diameter. knockout hole in the rear panel. Route incoming power in
conduit, through rear panel to icemaker electrical control box. Make connections to wires provided in the con-
trol box and ground lug/screw.
For WCC700A, WCC702A units, 8 ft. 2 inch long (2.4 m) power cord with 3-prong plug attached to the unit.
!
CAUTION:
Only trained and certified electrical technicians should replace the power cord or the unit should be returned to an
Authorized Service Center for power cord replacement. The replacement cord must meet all requirements of the
original equipment manufacturer.
Failure to comply could result in serious injury, death or damage to the equipment
2. Fused Line—should be checked and sized according to electrical rating shown on unit nameplate.
A
E
UGER
NGAGEMENT
Be certain that auger is fully engaged to lower drive and extruder head is fully engaged into evaporator. Perform the
following procedure to engage the auger properly.
1.
Install the extruder head on top of the evaporator, as shown in Figure 1.
2. When the auger is lowered into the evaporator, rotate the auger to engage the motor drive shaft, see Figure 2.
Publication Number: 630460174INS
Figure 1.
- 4 -
Auger/
Extruder
Head
© 2004-2013, IMI Cornelius Inc.