120.Volt.ac.equipment; B.. 120.Volt.ac.equipment - Four winns 318 VISTA Owner's Manual

Boats
Table of Contents

Advertisement

4.. To.disconnect.shore.power,.turn.off.the.main.
breaker.switch.on.the.AC.electrical.panel.and.
disconnect.the.power.cord.from.the.shore.power.
dockside receptacle first. Then, disconnect the
cord.from.the.boat.
NOTICE
Always disconnect the shore power cord from
the dockside first before disconnecting from
the boat.
NOTICE
Always remember to disconnect the shore
power cord from the dockside first before
leaving the dock. Properly store shore power
cord.
B. 120 Volt AC Equipment
All.12.volt.equipment.is.isolated.from.the.120.volt.AC.
system.(except.the.refrigerator.which.is.dual.voltage)..
Appropriately.labeled.circuit.breakers.protect.all.AC.
systems.on.the.boat..The.receptacles.can.be.used.for.
120.volt.(220.volts.on.50.Hertz.models).household.
appliances..Refer.to.the.following.list.for.information.
on.appliances.and.other.equipment.
Battery.Charger.-.The.battery.charger.is.controlled..
by.a.circuit.breaker.on.the.AC.electrical.panel.in.the.
cabin.labeled.BATTERY.CHARGER..In.order.for.the.
charger.to.charge.the.battery(s).the.circuit.breaker.
must be "ON" while connected to dockside power. .
If.a.generator.is.available.and.operating.it.too.will.
allow.the.batteries.to.be.charged.by.the.battery.
charger..
. .
Refrigerator.-.The.GALLEY.REFRIGERATOR.circuit.
breaker.must.be.on.to.operate.on.120.voltage..If.this.
breaker.is.off,.the.refrigerator.will.automatically.
operate.on.the.12.volt.system..This.can.deplete.the.
battery..Excessive.drain.on.the.battery.may.cause.
irreparable.battery.damage..The.refrigerator.will.
automatically.operate.on.120.volts.when.provided..
Refer.to.Section.L-1C.-.Galley.Equipment.in.this.
manual.for.more.information.
Water.Heater.-.The.WATER.HEATER.circuit.breaker.
supplies.power.to.the.water.heater..Refer.to.Section.
J-2C.-.Water.Heating.Systems.in.this.manual.for.more.
information.
Electrical Systems - Section H
NOTICE
DO NOT supply electrical power to an empty
water heater. Activate the FRESH WATER
circuit breaker and switch to start the water
pump and prime the system. Be sure there
is adequate water in the system before turning
on the water heater. Failure to comply will
result in immediate damage to the heater
element.
Electric.Stove.-.The.RANGE.circuit.breaker.must.be.
activated.to.supply.power.to.the.electric.stove..Refer.
to.Section.L-1A.-.Galley.Equipment.in.this.manual.for.
more.information.
Microwave.-.The.MICROWAVE.breaker.must.be.
activated.and.the.boat.connected.to.dockside.power.
or.use.the.generator.to.supply.power.to.the.micro-
wave.
Icemaker.-.The.icemaker.is.standard.on.the.318.
Vista
.models..The.COCKPIT.ICEMAKER/REFRIG-
®
ERATOR.breaker.located.on.the.AC.side.of.the.AC/
DC cabin panel must be "ON" to supply power to the
icemaker..
Receptacles.-.The.OUTLETS.circuit.breakers.supply.
power.to.the.corresponding.receptacles.in.the.AC.
system.
Air.Conditioner.-.The.AIR.CONDITIONER.circuit.
breaker.supplies.power.to.the.air.conditioner..The.318.
Vista
.models.have.dual.dockside.installation..With.a.
®
dual.dockside.installation,.one.inlet.is.dedicated.to.the.
air.conditioning.only.and.the.other.is.for.the."AC.Main.
Inlet". Refer to Section L-4 - Air Conditioning in this
manual.for.more.information.
Most.receptacle.circuits.are.capable.of.handling.15.
amperes..Refer.to.Table.III.for.a.list.of.equipment.and.
the.electrical.currents.usually.required.to.operate.
these.items..For.220.volt,.50.Hertz.models,.divide.all.
of.the.current.ratings.by.2..Usually,.the.power.require-
ment is specified on the electrical item. This is only an
approximation.of.the.electric.current.usage.normally.
experienced.
Owner's Manual Page 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents