Ni-4100 Specifications - AMX NetLinx NI-2100 Hardware Reference Manual

Netlinx integrated controllers
Hide thumbs Also See for NetLinx NI-2100:
Table of Contents

Advertisement

Introduction

NI-4100 Specifications

NI-4100 Specifications
Models Available:
Dimensions (HWD):
Power Requirement:
Memory:
Compact Flash:
Weight:
Enclosure:
Certifications:
Front Panel LEDs/Slots
LINK/ACT (green):
Status (green):
Output (red):
Input (yellow):
RS-232/422/485 (red):
Relay (red):
IR/Serial (red):
I/O (yellow):
NetLinx Control
Card Slots 1 - 4:
Rear Panel Components
RS-232/422/485
(Ports 1 - 7):
ICSNet:
ICSHub Out:
Relay (Port 8):
Digital I/O
(Port 17):
10
• NI-4100 64MB Controller (FG2105-06)
• NI-4100/256 256MB Controller (FG2105-26)
• 5 3/16" x 17" x 9 5/16" (13.2 cm x 43.2 cm x 23.7 cm)
• RU: 3
• 900 mA @ 12 VDC
NI-4100:
• 64 MB SDRAM
• 1 MB Non-volatile (NV) SRAM
NI-4100/256:
• 256 MB SDRAM
• 1 MB Non-volatile (NV) SRAM
2GB or greater (upgradeable to 4GB - see Other AMX Equipment).
Note: AMX may increase Flash size at any time in response to market availability.
9.15 lbs (4.15 kg)
Metal with black matte finish
FCC Part 15 Class B, CE, and IEC 60950
Blinks when the Ethernet cables are connected and terminated correctly. Also blinks
when receiving Ethernet data packets.
Blinks to indicate that the system is programmed and communicating properly.
Blinks when the Controller transmits data, sets channels On and Off, sends data
strings, etc.
Blinks when the Controller receives data from button pushes, strings, commands,
channel levels, etc.
Light to indicate that DB9 Ports 1 - 7 are transmitting or receiving RS-232, 422, or
485 data.
Light to indicate the relay channels 1 - 8 are active (closed). These LEDs reflect the
state of the relay on Port 8.
Light to indicate the IR/Serial channels 1 - 8 are transmitting control data on Ports 9
- 16. LED indictor for each IR port remains lit for the length of time that IR/Serial data
is being generated.
Light when the rear I/O channels 1 - 8 are active. The LED for each I/O port reflects
the state of that particular port.
Accepts up to 4 compatible NetLinx Cards (NXC-COM2, NXC-I/O10, etc.)
7 RS-232/422/485 control ports using DB9 (male) connectors with XON/XOFF
(transmit on/transmit off), CTS/RTS (clear to send/ready to send), and 300-115,200
baud.
2 RJ-45 connectors for ICSNet interface (provided by optional ICSNet daughter
card).
RJ-45 connector provides data to a Hub connected to the Controller (provided by
optional ICSNet daughter card).
• 8-channel single-pole single throw relay ports
• Each relay is independently controlled.
• Supports up to 8 independent external relay devices
• Channel range = 1-8
• Each relay can switch up to 24 VDC or 28 VAC @ 1 A
• Two 8-pin 3.5 mm mini-Phoenix (female) connectors provide relay termination
8-channel binary I/O port for contact closure with each input being capable of volt-
age sensing. Input format is software selectable with interactive power sensing for
IR ports.
NI-2100, NI-3100, NI-4100 Hardware Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netlinx ni-3100Netlinx ni-4100

Table of Contents