SCENIC
AIR CONDITIONING
Dehydration canister
Dehydration canister
REMOVAL
Drain the R134a refrigerant circuit using the filling
equipment (refer to the procedure described in the
"Air Conditioning" manual).
Remove:
– the right hand mudguard,
– the mounting bolts which secure the pipes to the
dehydration canister,
– the two mounting bolts of the dehydration
canister (B).
Fit plugs to every hole to prevent any penetration by
moisture into the components.
REFITTING
Refitting is the reverse of removal.
Oil the threads with P.A.G. SP 10 oil and check that
the seals are in good condition.
Create a vacuum then fill the R134a refrigerant circuit
using the filling equipment (refer to the procedure
described in the "Air conditioning" manual).
When changing the dehydration canister, add 15 ml of
P.A.G. SP 10 oil to the compressor.
16763R
62-3
62