Mitsubishi Electric FR-V500 Instruction Manual page 217

High precision & fast response vector inverter
Hide thumbs Also See for FR-V500:
Table of Contents

Advertisement

Outline dimension drawings
Dedicated motor outline dimension drawings (flange type)
Frame Number 90L
SF-V5RUF(H)
1K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 160M, 160L, 180M, 180L
SF-V5RUF(H)
11K
,
15K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
Earth (ground) terminal (M8)
cooling fan wind
Mark for earthing (grounding)
With guard wires
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Flange
Frame
KF
KF1
KF3
KF4
Number
No.
(kW)
(kW)
(kW)
(kW)
1
FF165
90L
2
1
FF215
100L
3
2
1
FF215 112M
5
3
2
FF265
132S
7
5
3
1
FF265 132M
11
7
5
2
FF300 160M
15
11
7
3
FF300
160L
18
FF350 180M
22
15
11
18
15
5
FF350
180L
30
7
FF400
200L
37, 45
22, 30
18, 22
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3. The size difference of top and bottom of the shaft center height is
4. The 400V class motor has -H at the end of its type name.
LR
KL
Q
LE
LN LZ
QK
A
B
B
A
W
S
Section BB
For cooling fan (A, B)
For motor (U, V, W)
For thermal protector (G1, G2)
A
B
U
V
W
G1
G2
,
18K
,
22K
LR
Q
LE
KL
QK
A
B
B
A
W
S
Section BB
For cooling fan (A, B, C)
Mass
(kg)
D
IE
KB
KD
KL
26.5
183.6
198.5
27
220
37
207
130
213
27
231
46
228
141
239
27
242
65
266
156
256
27
256
70
266
156
294
27
256
110
318
207
318
56
330
125
318
207
362
56
330
160
363
230 378.5
56
352
185
225
363
230 416.5
56
352
270
406
255
485
90
346
290
.
0
-0.5
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H)
2K
Connector (for encoder)
MS3102A20-29P
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Earthing (grounding)
terminal (M4)
Frame Number 200L
SF-V5RUF(H)
30K
Connector (for encoder)
MS3102A20-29P
LN LZ
Suction
Direction of
Earth (ground) terminal (M12)
cooling fan wind
Mark for earthing (grounding)
With guard wires
For motor (U, V, W)
Earthing (grounding)
terminal (M8)
For thermal protector (G1, G2)
Motor
LA
LB
LC
LE
LG
LL
LN
165 130j6 200
3.5
12
402
4
215 180j6 250
4
16
432
4
215 180j6 250
4
16
448
4
265 230j6 300
4
20
484
4
265 230j6 300
4
20
522
4
300 250j6 350
5
20
625
4
300 250j6 350
5
20
669
4
350 300j6 400
5
20
690
4
350 300j6 400
5
20
728
4
400 350j6 450
5
22
823.5
8
208
,
3K
,
5K
,
7K
LL
KB
LR
Q
LG
LE
KL
QK
Exhaust
Section
AA
B
B
W
S
Section BB
,
37K 45K
,
LL
KB
LR
Q
QK
LG
LE
Exhaust
Section
AA
B
B
KD
W
S
Section BB
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
Shaft End
LZ
LR
Q
QK
S
T
U
12
50
50
40
24j6
7
4
14.5
60
60
45
28j6
7
4
14.5
60
60
45
28j6
7
4
14.5
80
80
63
38k6
8
5
14.5
80
80
63
38k6
8
5
18.5
110
110
90
42k6
8
5
18.5
110
110
90
42k6
8
5
18.5
110
110
90
48k6
9
5.5
18.5
110
110
90
55m6
10
6
18.5
140
140
110 60m6
11
7
LN LZ
A
A
KL
LN LZ
A
A
(Unit: mm)
Terminal Screw Size
W
U,V,W A,B,(C) G1,G2
8
M6
M4
M4
8
M6
M4
M4
8
M6
M4
M4
10
M6
M4
M4
10
M6
M4
M4
12
M8
M4
M4
12
M8
M4
M4
14
M8
M4
M4
16
M8
M4
M4
18
M10
M4
M4