3.35 Display function (Pr. 867)

3.35.1 DA1 output response level adjustment (Pr. 867
You can adjust the response level of the output voltage of the output signal DA1.
Parameter
Name
867
DA1 output filter

3.36 Terminal function assignment (Pr. 868)

3.36.1 Terminal 1 function assignment (Pr. 868
The terminal 1 can be multi-functioned.
Parameter
Name
Terminal 1 function
868
assignment
<Terminal 1 function according to control>
Terminal 1
Pr. 868
Function under
Setting
Speed Control
Speed setting
0
auxiliary
(factory
*
setting)
Magnetic flux
1
command
Regenerative
2
torque limit
5
No function
9999
No function
* The function is changed to main speed according to the Pr.73 setting with which override, polarity reversible
function, etc. can be selected. (Refer to page 113.)
REMARKS
Refer to page 190 for bias/gain settings.
Factory Setting
Setting Range
0.05s
Factory Setting
0
Terminal 1 Function
Function under
under Torque Control
Position Control
Speed limit auxiliary
No function
Magnetic flux
Magnetic flux command
command
Regenerative
No function
torque limit
Forward/reverse rotation
speed limit
No function
(analog polarity
switchover speed limit)
No function
No function
183
Display function (Pr. 867)
speed
torque
Remarks
0 to 5s
Extended mode
speed
torque
position
Setting Range
Remarks
0, 1, 2, 5, 9999
Extended mode
Terminal 1
Bias/Gain Setting
Pr. 902 "speed setting
terminal 2 bias"
Pr. 903 "speed setting
terminal 2 gain"
Pr. 919 "terminal 1 bias
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain
(torque/magnetic flux)"
Pr. 919 "terminal 1 bias
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain
(torque/magnetic flux)"
Pr. 917 "terminal 1 bias
(speed)"
Pr. 918 "terminal 1 gain
(speed)"
No function
position
)
)
Remarks
Setting can be
made when
Pr. 810 = 1.
No function
3