Service Manual
8. Needle clearance to shuttle point - 2
B
If the clearance of needle and
shuttle is smaller on left side,
adjust support
right.
Tighten the bolt (A) after adjustment.
1. If the clearance of needle and shuttle point is not 0 to 0.1 mm, loosen a nut (D) on
support axis and turn the axis (E) to move it to front or back.
Clearance is too large → Turn it counter clockwise.
Clearance is too small → Turn it clockwise.
Tighten the nut (D) after adjustment.
NEEDLE
unit (B) toward
D
B
If the clearance of needle and
shuttle is smaller on right side,
adjust support
left.
E
Original issue
May 2009
Page 14/24
Model
HZL-27Z
B
unit (B) toward