Typical piping and wiring

TO
EXPANSION
TANK
VIBRATION
ELIMINATOR
GATE
VALVE
PUMP
NOTES:
1. Chiller must be installed level to within
2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are
for a quick overview of system and are not in accordance with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating,
Refrigerating, and Air Conditioning Engineers) handbook for details.
GATE
VALVE
FLOW
NOTE 5
NOTES:
1. Chiller must be installed level to within
2. Wiring and piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a
quick overview of system and are not in accordance with recognized standards.
3. All wiring must comply with applicable local and national codes.
4. All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating,
Refrigerating, and Air Conditioning Engineers) handbook for details.
5. Air separator required as close to chiller as possible (except primary/secondary systems).
30RAP UNITS WITHOUT HYDRONIC PACKAGE (SIZE 030 SHOWN)
VALVE
PRESSURE
GAGE
FLOW
SHUT OFF
VALVES
HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING
IF AMBIENT TEMPERATURE <32 F (0 C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM
1
/
in. per foot (10.4 mm per meter) to maintain proper compressor oil return and hydraulics.
8
30RAP UNITS WITH HYDRONIC PACKAGE (SIZE 030 SHOWN)
VIBRATION
ELIMINATOR
HEAT TAPE INSULATION IS RECOMMENDED ON ALL EXPOSED PIPING
IF AMBIENT TEMPERATURE <32 F (0 C) AND NO ANTIFREEZE SOLUTION IS IN SYSTEM
1
/
in. per foot (10.4 mm per meter) to maintain proper compressor oil return and hydraulics.
8
AIR FLOW
AIR FLOW
FIELD
CONTROL
POWER
WIRING
SUPPLY
LEGEND
Airflow Through Condenser
Power Wiring
Chilled Water Piping
a30-4867
FIELD
CONTROL
POWER
WIRING
SUPPLY
LEGEND
Airflow Through Condenser
Power Wiring
Chilled Water Piping
a30-4868
41