Facing Requirements

The fireplace is shipped with a set-up face that is 1/16" larger on the top, bottom and each side than the
faceplate. Leave the set-up face in place to act as a template when installing the facing.
The fireplace requires 1/2" thick concrete-board or other non-combustible to extend from the header to the
base of the fireplace and to the framing members on both sides (do not use sheetrock or drywall).
The non-combustible facing must extend a minimum of 12" above and 2-1/2" to each side of the faceplate.
The non-combustible facing must be a minimum 1" thick
Facing may be installed so it inserts behind
the faceplate. NOTE: the faceplate protrudes
1" from the front of the fireplace, has a 1/8"
overlap on the sides, and 1/4" overlap on top.
To achieve a facing that is flush with the
drywall to the side of the fireplace, recess the
framing directly next to the fireplace. See the
illustration below.
The combustible area above the facing must
not protrude more than 3/4" from the facing. If
it does, it is considered a mantel and must
meet the mantel requirements listed in this
manual.

TOP VIEW

(cross section of fireplace, framing, and face)
Fireplace
1-1/2"
1"
Flush Facing
Fireplace
Part # 17601185
44E - ZC Builder Booklet
TM
Nail Down Flange
(used to secure the
fireplace to the framing)
1/2"
Faceplate
1/8" (1/4" overalap on
top, 0" on bottom)
Framing
1/2" Drywall
1/2" Concrete Board
3/8" Tile
© 2002, Travis Industries, Inc.
12" (min.)
2-1/2"
(min.)
Overlapped Facing
Fireplace
Brick Facing
Fireplace
Cement-board must
extend from the header
to the floor and to the
framing members on
both sides.
Non-combustible
Facing
Keep the set-up face
on the fireplace when
installing the facing.
Framing
1/2" Drywall
1/2" Concrete Board
3/8" Tile
Framing
1/2" Drywall
Brick
Printed 3/8/02