CHAPTER 7 FIXING SYSTEM
2.2 Controlling the Temperature
The mechanism related to the control of fixing temperature consists of the following:
[1] Control in response to the operation of the power switch
[2] Control according to the type of paper
[3] Control at time of down sequence
[4] Control in ESS (energy save) mode
The sequence of control is as follows:
Main power
switch ON
Wait indication
Fixing heater
(H101)
200 C
190 C
180 C
170 C
140 C
7 - 4
COPYRIGHT© 2002 CANON INC.
Start key ON or
print signal input
STBY
Green
F07-202-01
PRINT
Red
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
End
STBY
Green
Heavy paper
mode
Plain paper
mode