Technical Data - Danfoss TripleLynx CN Installation Manual

Solar inverter
Table of Contents

Advertisement

5. Technical Data

5.1. Technical Data
Nomen-
Parameter
cla-
ture
1)
AC
P
Nom. power AC
ac,r
Reactive power range
V
AC voltage range (P-N)
ac,r
Nominal current AC
I
Max. current AC
acmax
AC current distortion (THD
%)
cosphi
Power factor at 100 % load > 0.98
ac,r
Controlled power
factor range
"Connecting" power loss
Night-time power loss (off
grid)
f
Grid frequency
r
DC
Nominal power DC
Max. recommended PV
power at STC
V
Nominal voltage DC
dc,r
V
-
MPP voltage - nominal
mppmin
V
3)
power
mppmax
MPP efficiency
V
Max. DC voltage
dcmax
V
Turn on voltage DC
dcstart
V
Turn off voltage DC
dcmin
I
Max. current DC
dcmax
Max. short circuit current
DC at STC
Min. on grid power
Efficiency
Max. efficiency
Euro efficiency, V at
Other
Dimensions (L,W,H)
Mounting recommendation
Weight
Acoustic noise level
MPP trackers
Operation temperature
range
Nom. temperature range
Storage temperature
Overload operation
Overvoltage category AC
Overvoltage category DC
5)
PLA
Reactive power
Functional Safety
Safety (protective class)
PELV on the communication
and control card
Islanding detection - loss of
mains
Voltage magnitude
Frequency
DC content of AC current
Insulation resistance
RCMU - Type B
Indirect contact protection
Short circuit protection
Table 5.1: Specifications
TripleLynx CN
8 kW
8000 W
10000 W
0-4.8 kVAr
0-6.0 kVAr
3 x 230 V ± 20 %
3 x 230 V ± 20 %
3 x 12 A
3 x 15 A
3 x 12 A
3 x 15 A
< 4 %
< 5 %
> 0.99
0.8 over-excited
0.8 over-excited
0.8 under-excited
0.8 under-excited
10 W
10 W
< 5 W
< 5 W
50 ± 5 Hz
50 ± 5 Hz
8250 W
10300 W
9500 Wp
11800 Wp
2)
700 V
700 V
345-800 V
430-800 V
99.9 %
99.9 %
1000 V
1000 V
250 V
250 V
250 V
250 V
2 x 12 A
2 x 12 A
2 x 12 A
2 x 12 A
20 W
20 W
97.9 %
98 %
97.0 %
97.0 %
dc,r
700 x 525 x 250
700 x 525 x 250
mm
mm
Wall bracket
Wall bracket
35 kg
35 kg
56 dB(A)
56 dB(A)
4
2
2
-25..60 °C
-25..60 °C
-25..45 °C
-25..45 °C
-25..60 °C
-25..60 °C
Change of operat-
Change of operat-
ing point
ing point
Class III
Class III
Class II
Class II
Included
Included
TLX CN+ and TLX
TLX CN+ and TLX
CN Pro+
CN Pro+
Class I
Class I
Class II
Class II
Three-phase moni-
Three-phase moni-
toring (ROCOF)
toring (ROCOF)
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Yes (class I, groun-
Yes (class I, groun-
ded)
ded)
Yes
Yes
L00410580-01_02
TripleLynx CN
TripleLynx CN
10 kW
12.5 kW
12500 W
0-7.5 kVAr
3 x 230 V ± 20 %
3 x 19 A
3 x 19 A
< 5 %
> 0.99
0.8 over-excited
0.8 under-excited
10 W
< 5 W
50 ± 5 Hz
12900 W
14700 Wp
700 V
358-800 V
99.9 %
1000 V
250 V
250 V
3 x 12 A
3 x 12 A
20 W
98 %
97.3 %
700 x 525 x 250
mm
Wall bracket
35 kg
56 dB(A)
3
-25..60 °C
-25..45 °C
-25..60 °C
Change of operat-
ing point
Class III
Class II
Included
TLX CN+ and TLX
CN Pro+
Class I
Class II
Three-phase moni-
toring (ROCOF)
Included
Included
Included
Included
Included
Yes (class I, groun-
ded)
Yes
5. Technical Data
TripleLynx CN
15 kW
15000 W
0-9.0 kVAr
3 x 230 V ± 20 %
3 x 22 A
3 x 22 A
5
< 5 %
> 0.99
0.8 over-excited
0.8 under-excited
10 W
< 5 W
50 ± 5 Hz
15500 W
17700 Wp
700 V
430-800 V
99.9 %
1000 V
250 V
250 V
3 x 12 A
3 x 12 A
20 W
98 %
97.4 %
700 x 525 x 250
mm
Wall bracket
35 kg
56 dB(A)
3
-25..60 °C
-25..45 °C
-25..60 °C
Change of operat-
ing point
Class III
Class II
Included
TLX CN+ and TLX
CN Pro+
Class I
Class II
Three-phase moni-
toring (ROCOF)
Included
Included
Included
Included
Included
Yes (class I, groun-
ded)
Yes
23