Removing The Inverter; Opening And Closing The Inverter - Danfoss TripleLynx CN Installation Manual

Solar inverter
Table of Contents

Advertisement

3. Installation

3.3. Removing the Inverter

Loosen the locking screws on either side of the inverter.
Removal is performed in the reverse order of mounting. With a firm grip at the lower end of the
inverter, lift the inverter approximately 20 mm vertically. Pull the inverter slightly away from the
3
wall. Push upwards at an angle until the wall plate releases the inverter. Lift the inverter away
from the wall plate.

3.4. Opening and Closing the Inverter

Illustration 3.7: Loosen Front Screws
12
Remember to observe all ESD safety regulations. Any electrostatic charge must be
discharged by touching the grounded housing before handling any electronic com-
ponent.
Use a TX 30 screwdriver to loosen the two
front screws. Turn the screwdriver until the
screws pop up. Screws are secured with a
spring and cannot fall out.
L00410580-01_02