Installation Configurations; Installation Clearances - Lennox G61MPV Engineering Data

Dave lennox signature collection multi−position − two−stage heat − variable speed blower gas furnaces
Hide thumbs Also See for G61MPV:

Advertisement

INSTALLATION CONFIGURATIONS

UP−FLOW
AIR FLOW
VENT
PIPING
HEAT
EXCHANGER
CONDENSATE
DRAIN
BLOWER
NOTE − On up−flow and down−flow configurations, the vent piping and
condensate drain can be moved to the other side of the unit. Vent piping
and drain must be installed on the same side of the unit with each other
unless optional Condensate Trap Alternate Location Kit (up−flow only) is
used. On horizontal installations the drain must be located at the bottom
and the vent piping at the top.

INSTALLATION CLEARANCES

NOTE − Air for combustion and supply air ventilation must conform to the methods outlined in American National
Standard (ANSI-Z223.1) National Fuel Gas Code or National Standard of Canada CAN/CGA-149.1, &
CAN/CGA-149.2 Installation Code for Gas Burning Appliances".
NOTE−In the U.S. flue sizing must conform to the methods outlined in current GAMA/A.G.A. venting tables, American
National Standard (ANSI-Z223.1) National Fuel Gas Code or applicable provisions of local building codes. In Canada
flue sizing must conform to the methods outlined in National Standard of Canada CAN/CGA-149.1 and .2.
1
Allow proper clearances to accommodate condensate trap and vent pipe installation.
2
Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.
DOWN−FLOW
BLOWER
VENT
PIPING
HEAT
EXCHANGER
CONDENSATE
DRAIN
AIR FLOW
Sides
Rear
Top/Plenum
Front
Front (service/alcove)
Floor
HORIZONTAL − RIGHT
BLOWER
HORIZONTAL − LEFT
VENT
PIPING
HEAT
EXCHANGER
AIR
FLOW
CONDENSATE
DRAIN
1
0 inches (0 mm)
0 inches (0 mm)
1 inch (25 mm)
0 inches (0 mm)
24 inches (610 mm)
2
Combustible
VENT
PIPING
HEAT
EXCHANGER
AIR
FLOW
CONDENSATE
DRAIN
BLOWER
G61MPV / Page 9