Maintenance / Cleaning; Maintenance; Cleaning The Pipe System In The Heat Exchanger; Cleaning The Air System - Dimplex LAS 10MT Installation And Operating Instructions Manual

Air-to-water heat pumps for swimming pool heating (outdoor installation)

Advertisement

9

Maintenance / Cleaning

9.1 Maintenance

To protect the paintwork, avoid leaning or putting objects on the
device. External heat pump parts can be wiped with a damp cloth
and domestic cleaner.
ATTENTION!
Never use cleaning agents containing sand, soda, acid or chloride as
these can damage the surfaces.
To prevent faults due to sediments in the titanium heat
exchanger of the heat pump, ensure that the heat exchanger
cannot be contaminated (water treatment and filter system nec-
essary). In the event that operating malfunctions due to contam-
ination still occur, the system should be cleaned as described be-
low. (Warning: the fins on the finned tube heat exchanger are
sharp-edged -> danger of being cut!)
9.2 Cleaning the Pipe System in
the Heat Exchanger
Contamination in the pipes and heat exchanger can reduce the
performance of the heat pump's titanium heat exchanger. If this
is the case, the pipe system and heat exchanger must be
cleaned by a technician.
Use only pressurised drinking water for cleaning.

9.3 Cleaning the Air System

The finned heat exchanger, ventilator and condensate outflow
should be cleaned of contaminants (leaves, twigs, etc.) before
each new heating period. These types of contaminants can be
manually removed using compressed air or by flushing with
clean water.
It may be necessary to remove the device cover and air inlet grid
first.
ATTENTION!
Before opening the device, ensure that all circuits are isolated from the
power supply.
To prevent the evaporator and the condensate tray from being
damaged, do not use hard or sharp objects for cleaning.
Under extreme weather conditions (e.g. snow drifts), ice may
form on the air intake and exhaust air outlet grids. If this happens,
the ice must be removed in the vicinity of the air intake and ex-
haust air outlet grids to ensure that the minimum air flow rate is
maintained.

9.4 Winter Shutdown / Lay-Up

If there is a chance of frost after the bathing-season has ended
when the swimming pool heating is switched off and the external
temperature is expected to drop below the operating limit, the
water circuit of the heat pump should be completely drained. Oth-
erwise, suitable constructional measures should be taken by the
customer to protect the heat pump against damage from frost.
ATTENTION!
The warranty does not cover damage caused by inadequate lay-up
measures during the winter.
www.dimplex.de
10 Faults / Trouble-
Shooting
This heat pump is a quality product and is designed for trouble-
free and maintenance-free operation. However, if a fault does oc-
cur, use the following information to check whether you can elim-
inate the fault yourself.
The heat pump will not run!
Please check whether:
There is supply voltage (tripped fuse, power failure).
The operating switch on the remote control is switched on,
and whether the correct setpoint temperature has been set.
The set temperature level cannot be reached!
Please check whether:
The permissible operating conditions for the heat pump
have been adhered to (air temperatures too high or too low).
The air inlet or outlet area is blocked, restricted or very dirty.
There are closed valves or stop-cocks in the water pipes.
If you cannot correct the fault yourself, please contact your after-
sales service technician (see Warranty Certificate).
Work on the heat pump may only be carried out by authorised
and qualified after-sales service technicians.
11 Decommissioning/
Disposal
Before removing the heat pump, disconnect it from the power
source and close all valves. Observe all environmentally-relevant
requirements regarding the recovery, recycling and disposal of
materials and components in accordance with all applicable
standards. Particular attention should be paid to the proper dis-
posal of refrigerants and refrigeration oils.