DP6060 Dual-Input Process Meter

Configuration for 12 or 24 VDC Power Option

Do not exceed voltage rating of the selected
configuration.
Warning!
Meters equipped with the 12/24 VDC power option are shipped
from the factory ready to operate from 24 VDC.
To configure the meter for 12 VDC power:
1.
Remove all the connectors.
2.
Unscrew the back cover.
3.
Slide the back cover about 1 inch.
4.
Configure the J9 jumper, located behind the power
connector, for 12 V as shown below.
M-LINK
24 VDC
12 VDC
POWER

Figure 5. Jumper Configuration for 12/24 VDC Power

MAIN BOARD
+
J9
_
J9 CONFIGURATION
24 V
12 V
20
Instruction Manual