Remote Output Control Options And Control Cable Assemblies; K443-1 Ln-25 Contactor Kit; K431-1 Remote Output Control Kit; K433 Power Source Remote Box - Lincoln Electric LN-25 Service Manual

Semiautomatic wire feeder
Hide thumbs Also See for LN-25:
Table of Contents

Advertisement

C-4

K443-1 LN-25 CONTACTOR KIT

(Factory installed in K449 Model.)
The internal contactor provides "cold" electrode until
the gun trigger is pressed, and a fixed burnback time
delay to prevent electrode from sticking in the weld
crater when the trigger is released. The contactor is
rated for use up to 300 amps. A cold inch switch
allows the wire to be loaded into the system without
being electrically "hot".
Installation Instructions (L9676) are included with
the kit.
CAUTION
This kit can only be used with LN-25's above Code
9200 or with LN-25's equipped with a G1757-3 (or
higher part number) Control PC board. To prevent
possible damage to the LN-25 with internal contactor,
do not connect to non-Lincoln TIG or Square Wave
power sources. TIG high frequency power should
never be applied to the LN-25.
NOTE: The K443-1 cannot be used with K431-1 or
K624-1 Remote Output Control Kit. If remote voltage
control is desired along with the internal contactor,
obtain a K444, K444-1 or K444-2 Remote Voltage
Control Kit.
REMOTE OUTPUT CONTROL
OPTIONS AND CONTROL CABLE
ASSEMBLIES
Remote Output Control Options are available to pro-
vide the LN-25 with the following additional features:
1. "Cold" electrode until the gun trigger is pressed,
and a fixed burnback time delay to prevent elec-
trode from sticking in the weld crater when the
gun trigger is released.
2. Remote (10K ohm rheostat) control of power
source output arc voltage level.
K431-1 REMOTE OUTPUT CONTROL
KIT
(For use with K432 Remote Control Cable and K433
Power Source Remote Box.)
ACCESSORIES
The Kit includes a Remote PC board and control
cable receptacle which mount and connect inside the
LN-25 control box per the Installation Instructions
(M17584) included with the kit.
NOTE: If the K431-1 Remote Output Control Kit is
installed but the LN-25 is to be used without the K432
Remote Control Cable Assembly, then the Remote
Board harness plug must be removed from the 12-
pin receptacle on the Control Board and the jumper
plug (T13498-21) reinstalled.

K433 POWER SOURCE REMOTE BOX

(Requires K431-1 Remote Output Control Kit installed
in LN-25 using K432 Remote Control Cable.)
The Remote Box is designed to mount and connect
to Lincoln Idealarc
the Installation Instructions (M15324) and power
source connection diagrams included with the kit.
The Remote Box provides the proper welding power
source control interface and isolated 24V AC input
supply for the LN-25 equipped with the K431-1
Remote Output Control Kit.
Remote Box requires 115V AC, 50/60 Hz input and a
welding power source using a contact closure output
pilot circuit, as available on appropriate Lincoln weld-
ing power sources.
K432 REMOTE CONTROL CABLE
ASSEMBLY
(Requires K431-1 Remote Output Control Kit installed
in LN-25 and K433 Remote Box mounted to power
source with 115V AC auxiliary power.)
The K432 control cable assemblies include an elec-
trode cable, rated for up to 500 amps 60% duty cycle,
and a 6-conductor control cable with pin connectors
on both ends. Available in 25, 50, 75 and 100 ft.
lengths.
The cable assembly end with the socket pin connector
connects to the LN-25 per the Instructions (M17584)
included with the K431-1 kit.
The cable assembly end with the male pin connector
connects to the K433 and power source per the In-
structions included with the K433 kit.
LN-25
®
semiautomatic power sources per
C-4