Samsung MH040FXA2B Installation Manual page 9

Free joint multi & multi-split type room air conditioner
Table of Contents

Advertisement

MH18VF1X/MH19VF1X

Indoor unit
MH18VF1-09
MH19VF1-07
MH19VF1-12
Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
CAUTION:
3 m as minimum pipe length: It will reduce
noise and vibration.
This value must be increased at 7.5 meters
in case it is connected just one indoor unit.
100 mm
or more
300 mm
minimum
600 mm
minimum
Piping length and the height
Dimension
Composition
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
08'FJM_OUTDOOR_28896A_IM_E.indd 9
Power supply
Outdoor unit
Ø, V, Hz
MH18VF1X
1,220-240~, 50
MH19VF1X
200 mm
or more
A-unit
600 mm
A
minimum
300 mm
minimum
1 Room max
2 Room total max
length
length
20m
30 m
A,B
A+B
Make at least one round:
It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
Piping outside diameter
Unit
MH18VF1-09
MH19VF1-07
MH19VF1-12
B-unit
or
MH18VF1-09
MH19VF1-12
or
MH19VF1-07
MH18VF1-09
(h)
160 mm
or more
B
Main power switch
Max height between
indoor unit & outdoor unit
15m
(H)
PREPARING THE INSTALLATION
Outer Diameter
Liquid
Gas
1/4"
3/8"
(H)
Max height between
indoor units
7.5 m
(h)
9
E-
2007-12-12 14:28:13