Samsung MH040FXA2B Installation Manual page 7

Free joint multi & multi-split type room air conditioner
Table of Contents

Advertisement

MH060FXA3B

Indoor unit
020/023/026/030/035/052
100 mm
or more
CAUTION:
3 m as minimum pipe length: It will reduce
noise and vibration.
This value must be increased at 7.5 meters in
case it is connected just one indoor unit.
300 mm
minimum
600 mm
minimum
Piping length and the height
1 Room max
Dimension
Composition
System can work with one indoor unit connected, but it is recommended that the TOTAL number
of indoor unit suggested by manufacturer are connected to obtain the maximum performance.
08'FJM_OUTDOOR_28896A_IM_E.indd 7
Power supply
Outdoor unit
Ø, V, Hz
MH060FX
A3B
1,220-240, 50
200 mm
or more
160 mm
or more
A
600 mm
minimum
300 mm
minimum
3 Room total max
length
length
20m
45 m
A,B,C
A+B+C
Make at least one round:
It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
Piping outside diameter
Unit
020/023/026/030/035
052
B
Main power switch
Max height between
Max height between
indoor unit & outdoor unit
indoor units
15m
7.5 m
(H)
(h)
PREPARING THE INSTALLATION
Outside diameter
Liquid
Gas
3/8"
1/4"
1/2"
(h) (H)
C
2007-12-12 14:28:07