Samsung MH040FXA2B Installation Manual
Samsung MH040FXA2B Installation Manual

Samsung MH040FXA2B Installation Manual

Free joint multi & multi-split type room air conditioner

Advertisement

Free Joint Multi & Multi-Split Type Room Air Conditioner
E
S
F I P D G
DB98-28896A(2)
INSTALLATION
MANUAL
Free Joint
MH040FX
MH050FX
MH060FX
MH070FX
MH080FX
(Cooling and Heating)
Fixed
MH18VF1X
A2B
MH19VF1X
A2B
A3B
A4B
A4B

Advertisement

Table of Contents
loading

Summary of Contents for Samsung MH040FXA2B

  • Page 1 INSTALLATION MANUAL Free Joint Fixed MH18VF1X MH040FX  MH19VF1X MH050FX  MH060FX  MH070FX  MH080FX  Free Joint Multi & Multi-Split Type Room Air Conditioner (Cooling and Heating) F I P D G DB98-28896A(2)
  • Page 2: Safety Precautions

    Store the operation and installation manual in a safe location and remember to hand it over to the new owner if the air conditioner is sold or transferred. This manual explains how to install an indoor unit with a split system with two SAMSUNG units. The use of other types of ...
  • Page 3: Table Of Contents

    Contents REPARING THE NSTALLATION  Deciding on Where to Install the Air Conditioner ..... . 4    ........12 Air Conditioner and Accessories ...
  • Page 4: Preparing The Installation

    PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases ...
  • Page 5 PREPARING THE INSTALLATION MH040FXA2B  Piping outside diameter Power supply Outside diameter Indoor unit Outdoor unit Unit Ø, V, Hz Liquid MH040FX  1,220-240, 50 020/023/026/035 1/4" 3/8" 020/023/026/035 A2B outdoor unit cannot be connected to the following indoor unit combination. MH040FX ...
  • Page 6 PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner (Continued) MH050FXA2B  Piping outside diameter Power supply Outside diameter Indoor unit Outdoor unit Unit Ø, V, Hz Liquid 3/8" 020/023/026/035 MH050FX 1,220-240, 50 020/023/026/035/052  1/4" 1/2" 052 A2B outdoor unit cannot be connected to the following indoor unit combination.
  • Page 7 PREPARING THE INSTALLATION MH060FXA3B  Piping outside diameter Power supply Outside diameter Indoor unit Outdoor unit Unit Ø, V, Hz Liquid 3/8" 020/023/026/030/035 MH060FX  1,220-240, 50 020/023/026/030/035/052 1/4" 1/2" 052 200 mm or more 100 mm 160 mm or more or more CAUTION: (h) (H)
  • Page 8 PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner (Continued) MH070FXA4B / MH080FXA4B  Piping outside diameter Power supply Outside diameter Indoor unit Outdoor unit Unit Ø, V, Hz Liquid MH070FXA4B 1/4" 3/8" 020/023/026/030/035 1,220-240, 50 020/023/026/030/035/052 1/4" 1/2"...
  • Page 9 PREPARING THE INSTALLATION Piping outside diameter MH18VF1X/MH19VF1X  Power supply Outer Diameter Indoor unit Outdoor unit Unit Ø, V, Hz Liquid MH18VF1-09 MH18VF1X MH18VF1-09 MH19VF1-07 1/4" 3/8" MH19VF1-07 1,220-240~, 50 MH19VF1X MH19VF1-12 MH19VF1-12 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. CAUTION: B-unit MH18VF1-09...
  • Page 10 PREPARING THE INSTALLATION Deciding on Where to Install the Air Conditioner (Continued) Space Requirements for Outdoor Unit When installing 1 outdoor unit Unit : mm  W hen the air outlet is opposite the wall  W hen the air outlet is towards the wall ...
  • Page 11 PREPARING THE INSTALLATION When installing more than 1 outdoor unit Unit : mm  When the air outlet is towards the wall 300 or more 600 or more 600 or more 600 or more  When 3 sides of the outdoor unit are blocked by the wall 600 or more 600 or more ...
  • Page 12: Air Conditioner And Accessories

    PREPARING THE INSTALLATION Air Conditioner and Accessories The following accessories are supplied with the air conditioner. Accessories in the Outdoor Unit Case  MH040FXA2B/MH050FXA2B/MH060FXA3B/MH18VF1X/MH19VF1X 3-wire 2-wire Drain Plug Transmitter power Energy Label Power Cable Assembly Cable cable (option) (option) Rubber Leg Flare Bolt Installation Manual (Nut 1/2”, Bolt 3//8”)
  • Page 13: Installing The Indoor Unit

    INSTALLING THE INDOOR UNIT Installing and Connecting the Drain Hose of the Outdoor Unit While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following: Insert the drain plug into the drain hole on the underside of the outdoor unit. Connect the drain hose to the drain plug.
  • Page 14: Cutting/Extending The Piping

    INSTALLING THE INDOOR UNIT Cutting/Extending the Piping Make sure that you have the required tools available (pipe cutter, reamer, flaring tool and pipe holder). If you wish to shorten the piping, cut it using a pipe cutter, taking care to ensure that the cut edge remains at a 90°...
  • Page 15: Installing The Outdoor Unit

    INSTALLING THE OUTDOOR UNIT Connecting the Cables to the Outdoor Unit When you install the unit, make first refrigerant connections and then elec- trical connections.Connect the air conditioner to grounding system before performing the electrical connection.If unit is uninstalled first disconnect electrical cables, then refrigerant connections.
  • Page 16 INSTALLING THE OUTDOOR UNIT Connecting the Cables to the Outdoor Unit(Continued) MH060FXA3B B-unit C-unit A-unit Indoor unit 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) Assembly cable F1 F2 F1 F2 F1 F2 Earth Earth Earth terminal terminal terminal F1 F2 F1 F2 F1 F2 Earth Earth...
  • Page 17 INSTALLING THE OUTDOOR UNIT MH070FXA4B / MH080FXA4B A-unit B-unit Indoor unit C-unit D-unit 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) 1(L) 2(N) Assembly cable F1 F2 F1 F2 F1 F2 F1 F2 Earth Earth Earth Earth terminal terminal terminal terminal F1 F2 F1 F2 F1 F2 F1 F2...
  • Page 18 INSTALLING THE OUTDOOR UNIT Connecting the Cables to the Outdoor Unit (Continued) Preparation of cables for outdoor unit terminal block  Main power supply cable: L(mm) Cable of indoor unit Main Power L(mm)  Power cable to indoor units: L(mm) Cable of Remark indoor unit...
  • Page 19: Transmitter Installation (Optional)

    INSTALLING THE OUTDOOR UNIT Transmitter Installation (Optional)  MH040FXA2B/MH18VF1X/MH19VF1X Accessories (Transmitter: MIM-B13) Transmitter Transmitter power Transmitter Installation Manual Case Cable-tie cable communication cable Bolts spec. 7seg. LED Fix the case at with bolts on the side of the control box in the outdoor unit. Display side (See the picture) Attach the transmitter PCB to the case in the control box in the outdoor...
  • Page 20 INSTALLING THE OUTDOOR UNIT Transmitter Installation (Optional) (Continued)  MH050FXA2B/MH060FXA3B/MH070FXA4B / MH080FXA4B Accessories (Transmitter: MIM-B13) Transmitter Transmitter power Transmitter Installation Manual Case Cable-tie cable communication cable MH050FXA2B Terminal side Transmitter 7seg. LED Display side Bolts spec. Fix the case with bolts on the control box in the outdoor unit. (See the picture) Attach the transmitter PCB to the case in the control box in the outdoor unit, then connect the power and the communication cable between the...
  • Page 21 INSTALLING THE OUTDOOR UNIT Transmitter power cable CN01 (Accessory in the outdoor unit) (Whit) Transmitter CN03 (Blue) CN01 MH040FXA2B MH050FXA2B/MH060FXA3B (Whit) MH18VF1X/MH19VF1X MH070FXA4B/MH080FXA4B Center Controller Outdoor unit PCB Transmitter communication One housing is used for connection cable (Accessory in the although there are 2 housings on the transmitter) communication cable.
  • Page 22: Checking Correct Earthing

    INSTALLING THE OUTDOOR UNIT Checking Correct Earthing If the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner. Select an earthing electrode that complies with the specifications given in the illustration opposite.
  • Page 23: Completing The Installation

    COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit The outdoor unit is loaded with sufficient R410A refrigerant.Do not vent R-410A into atmosphere: it is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global Warming Potential (GWP) = 1975. You should purge the air in the indoor unit and in the pipe.
  • Page 24: Adding Refrigerant

    COMPLETING THE INSTALLATION Connecting Up and Purging the Circuit(Cont.)  MH060FXA3B/MH070FXA4B / MH080FXA4B Check the piping connections. Connect the charging hose of low pressure side of manifold gauge to the packed valve having a service port (5/8” Packed valve) as shown at the figure (Value stem: 1/2”...
  • Page 25: Performing Leak Tests

    COMPLETING THE INSTALLATION Important information regulation regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type GWP value CAUTION R410A 1975 Inform user if system contains 3 kg or more of fluorinated greenhouse gases. In this ...
  • Page 26: Pipe Installation With Indoor Units

    COMPLETING THE INSTALLATION Pipe Installation with Indoor Units  MH070FXA4B / MH080FXA4AB Follow different orders depending on the capacity of indoor units. MH020/023/026/030/035FEA OUTDOOR UNIT  Install pipes between indoor and outdoor units orderly as[AB CD]. MH052FEA  Install pipes between indoor and outdoor units orderly as [ CD]. Examples ...
  • Page 27: Switch Setting And Testing Operation

    COMPLETING THE INSTALLATION Switch Setting and Testing Operation To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly. Step 1 Review all the following elements in the installation:  Installation site strength ...
  • Page 28 COMPLETING THE INSTALLATION Switch Setting and Testing Operation(Cont.) TO SET ADDRESSING MANUALLY BY TYPE PICTURE MODEL ROTARY SWITCH “SW02” Same for: MH020FV(N)EA MH023FBEA MH026FB(V/N)EA MH035FB(V/N)EA MH052FB(V/N)EA MH026FKEA 1 WAY CASSETTE MH035FKEA MH030FMEA MINI 4 WAY MH035FMEA MH052FMEA MH026FEEA SLIM DUCT MH035FEEA MSP-DUCT MH052FUEA...
  • Page 29 COMPLETING THE INSTALLATION ROTARY SWITCH “SW02” POSITION ACCORDING TO REFRIGERANT CIRCUIT CONNECTED ( 0=A; 1=B; 2=C; 3=D ) OUTDOOR UNIT Indoor Unit SW02 A unit B unit Indoor Unit OUTDOOR UNIT SW02 A unit B unit C unit Indoor Unit SW02 OUTDOOR UNIT A unit...
  • Page 30 COMPLETING THE INSTALLATION Switch Setting and Testing Operation (Cont.) It could take maximum 60 minutes to operate for the protection of the compressor  if the outdoor temperature is below -5°C. Ampere Limit Setting & Changing Procedure WARNING  Do not adjust the “Ampere Limit Switch”, if it’s not necessary: before modifying it, evaluate the total number of electric and electronics loads consumption and use “Ampere limits switch”...
  • Page 31 COMPLETING THE INSTALLATION Pipe Checking Operation (Auto Addressing Mode) Automated checking of pipe connection (Auto addressing option) Turn on the outdoor unit and wait for one minute. During these 60 seconds, the left dispaly DIS01 will show sequentially 00-01-02-03-...15-00. E199 is showed on the display PCB of outdoor unit. - It means you didn’t do “Pipe check operation“...
  • Page 32 COMPLETING THE INSTALLATION Switch Setting and Testing Operation (Cont.) Settings of PCB Display of the Outdoor unit Key Options of PCB Display - K1 : pipe checking operation button - K2 : Function button - K3 : Reset button - K4 : View mode change button SW02 SW01 Push...
  • Page 33: Troubleshooting

    COMPLETING THE INSTALLATION Troubleshooting The table below give indication about self diagnostic routine. Some of error code requires activities exclusively for Authorise Service Center. The error indicated on the PCB display of outdoor unit DISPLAY EXPLANATION (The error indicated on the PCB display of outdoor unit) REMARK Check electrical connection Communiaction error(indoor unable to receive data)
  • Page 34: Explaining Operations To The Owner

    COMPLETING THE INSTALLATION Troubleshooting (Cont.) The table below give indication about self diagnostic routine. Some of error code requires activities exclusively for Authorise Service Center. The error indicated on the PCB display of outdoor unit DISPLAY EXPLANATION (The error indicated on the PCB display of outdoor unit) REMARK check pipe lenght, indoor Outdoor unit freezing(Compressor stop)
  • Page 35: Combination Table

    COMBINATION TABLE 08'FJM_OUTDOOR_28896A_IM_E.indd 35 2007-12-12 14:29:02...
  • Page 36 08'FJM_OUTDOOR_28896A_IM_E.indd 36 2007-12-12 14:29:02...

Table of Contents