Bootloader Errors (Continued)
Table 4-1
Error Text
Number
Insufficient memory
-20
for buffering data
Insufficient data
-21
available to
complete record
Invalid Symbol
-23
HEX file
Unrecognized or
-24
unsupported HEX
record
Invalid data in HEX
-25
file
Exceeded max size
-26
Partition is not valid
-27
on this device
Wrong destination
-28
code
Non-contiguous
-30
record found
Timed Out - No
-31
data
Invalid file format
-33
Partition Table not
-34
Valid
Invalid data in file
-35
File cannot be
-38
loaded to this unit
File validation failed -40
Error
There is no more heap space available for the download
procedure. Restart Bootloader and retry the download. If the
failure persists, contact service with details of what is being
downloaded.
A HEX file download was attempted but the HEX file is invalid.
Ensure the file is in proper HEX file format.
A HEX file download was attempted but the HEX file is invalid.
Ensure the file is in proper HEX file format.
The HEX file being downloaded contains an invalid or
unrecognized HEX record. Ensure the file is in proper HEX file
format.
The HEX file being downloaded contains invalid data. Ensure the
file is in proper HEX file format with valid HEX data.
The download file is too large to fit into the space allocated for it.
Either make the file smaller or increase the space allocated for it
by altering the partition table.
The downloaded file specifies a partition entry that does not exist
on the device. Only download files that are valid for this device, or
change the partition table so that the new file is valid on the
device.
A specific partition was chosen from the Bootloader main menu
but the file selected for download was for another partition.
Ensure that the partition selected from the Bootloader main menu
matches the file selected for download.
A HEX file download was attempted but the HEX file is invalid.
Ensure the file is in proper HEX file format.
Bootloader was waiting for data from the source device but timed
out before receiving any. Check the source device connectivity
and retry.
The file format is invalid. Only HEX files are supported by
Bootloader.
The size of flash memory is different than that described in the
partition table. Retry the download with the correct partition table
file.
The .bin or .sig file being downloaded contains invalid data.
Ensure the file is in proper file format.
The file contains valid data that indicates it cannot be loaded onto
the device.
The file has either been signed incorrectly, or contains data that
indicates that it cannot be loaded onto the terminal.
Application Development 4 - 15
Probable Cause