Servicing Air Cleaner (Kohler-Powered Units) - Hobart Champion 10,000 Owner's Manual

Stick (smaw) welding, engine driven welding generator
Hide thumbs Also See for Champion 10,000:
Table of Contents

Advertisement

Repair or replace cracked
cables.
Blow out or vacuum inside.
During heavy service, clean
monthly.

9-3. Servicing Air Cleaner (Kohler-Powered Units)

OM-945 Page 30
Every 500 h
Service welding generator
brushes and slip rings. Service
more often in dirty conditions.*
Every 1000 h
OR
Y Stop engine.
Y Do not run engine without air
cleaner or with dirty element.
1
Wrapper (Foam Element)
1
Wash wrapper with soap and water
solution. Allow wrapper to air dry
completely.
Spread 1 tablespoon SAE 30 oil
2
evenly into wrapper. Squeeze out
excess oil.
2
Element
Replace element if dirty, oily, or
damaged.
aircleaner3 1/97 – 802 772 / Ref. 183 175-A / S-0759