Recharging - Derbi GP1 125-250 c.c. Workshop Manual

Gp1 125-250 c.c.
Table of Contents

Advertisement

N.B.
CARRY OUT THE MEASUREMENT WITH A DIGITAL VOLT-
METER (A) THAT CAN READ VOLTAGES WITH DECIMAL FI-
GURES.
* IF THE READING IS BELOW THAT SPECIFIED, THE BATTERY
NEEDS TO BE RECHARGED.
Battery terminal voltage
Standard:
12.5v or higher
- Measure the voltage at the battery terminals.
R
R
ECHARGING
ECHARGING
- Disconnect the cables from the battery terminals (see ins-
pecting the charging conditions).
- Remove the battery (A).
- Carry out the recharging by following the method, and ac-
cording to the voltage at the battery terminals.
WARNING
THIS BATTERY IS THE HERMETIC (AIRTIGHT) TYPE. NE-
VER REMOVE THE CLOSING PLUGS (B), NOT EVEN WHEN
CHARGING. NEVER ADD WATER.
CARRY OUT THE CHARGING WITH THE CURRENT AND FOR
THE PERIOD INDICATED BELOW.
Battery terminal voltage: 11.5 – Less than 12.5V
Standard charge:
0.4A x 5 - 10h (see the graph on the following page)
234
(V)
SE REQUIERE
RECARGA
NOTA
BUENA

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp1 125 c.c.Gp1 250 c.c.

Table of Contents