Download Print this page

EverFocus ED Series User's Manual And Operation Instructions page 13

High resolution dome camera series

Advertisement

(1) IRIS ALC Adjustment
To select light metering method –
Turn the IRIS ALC Adjustment VR counterclockwise for Average
Metering.
Turn the IRIS ALC Adjustment VR clockwise for Peak Metering.
(2) IRIS Level Adjustment
Brightness Level can be adjusted from the IRIS level VR while using the
direct drive lens.
Turn counterclockwise to L to get darker picture.
Turn clockwise to H to get brighter picture.
(3) Flickerless
When picture flicker fiercely, turn FL on, then the camera will stabilize
the speed of electronic shutter at 1/100(NTSC) or 1/120(PAL)
automatically, and reduce the flicker immediately.
The default setting is OFF.
(4) Auto Gain Control Adjustment
AGC ON:
The sensitivity increases automatically when the light is low.
AGC OFF: A low-noise picture is obtained under a low light condition.
10
Deleted: Normal

Advertisement

loading

This manual is also suitable for: