3
4
5
6
37
4. Turn the fuel tank cap air vent knob and fuel cock
knob to ON.
3 ON
4 ON
5. Start the engine and leave it run until it stops.
7DK-035
The engine stops in approximately 20 minutes
time by running out of fuel.
TIP
9 Do not connect with any electrical devices.
(unloaded operation)
9 Duration of the running engine depends on the
amount of the fuel left in the tank.
7DK-038
6. Remove the screws, and then remove the cover.
5 Screw
6 Cover
7PB-030
7. Drain the fuel remaining in the carburetor into an
7
approved container by loosening the drain screw
on the carburetor float chamber.
7 Drain screw
8. Tighten the drain screw.
7DK-071
9. Turn the engine switch to "5" (STOP).
10. Turn the fuel cock knob to OFF.
11. Install the cover and tighten the screws.
12. Turn the fuel tank cap air vent knob to OFF after
the engine has completely cooled down.
13. Tighten further if any screws, bolts and nuts are
loose.
14. Store the generator in a dry, well-ventilated place,
with the cover placed over it.